CONNECTING PELCONET TO A CM9760-DT FOR REMOTE BROWSER
CONTROL
Refer to Figure 46. This configuration lets an operator view and control cameras on a PC using a
web browser. (The operator’s PC is not shown on the diagram.)
Figure 46.
  Using PelcoNet with CM9760-DT to Provide Remote Control of a 9760 Monitor Output
 VIDEO 1
 VIDEO 2
 VIDEO 3
 VIDEO 4
AUDIO IN
AUDIO OUT
INPUTS
OUTPUTS
RS-232/422/485
ETHERNET
 10/100 BASE-T
POWER
PELCONET
 TRANSMITTER
TRANSP
ARENT
 DA
T
A
 POR
T
CM9760-MXB 
USING INTERNET
 EXPLORER
SET
 TRANSPOR
T
 SETTINGS:
BAUD RA
TE
DA
T
A
 BITS
PA
R
ITY
ST
OP
 BITS
VIDEO
SPECTRA
 “P”
PROT
OCOL
CM9760-CC1 
CM9760-KBD CM9505-UPS 
PELCONET CM9760-DT SETUP
2-RX 3-TX 5-GND
CM9760-DT1 
12V
AC
1 ON 
2 OFF
COM A
COM B
2-RX 3-TX 5-GND
NULL
 MODEM
CABLE NOT
SUPPLIED
SUPPLIED
CABLE
DIP
 SWITCH
COM 1
C
OM 2
COM 2 PROGRAMMED FOR 9760-DT
CA
T
 5
TO
 NETWORK
(LAN/W
AN)
*
4800 OR 9600
8
EVEN OR ODD
1
NOTE: 4800 BAUD 
AND EVEN P
A
RITY
 APPLIES 
T
O
 CM9760-DT
 VERSION 2.07,
            WHILE 9600 BAUD 
AND ODD P
A
RITY
 APPLIES 
T
O