Справочник Пользователя для Pelco PELCO SDS Series C1487M-D

Скачать
Страница из 50
16
Pelco Manual C1487M-D (7/99)
Table D.  Switch Settings for SW2 – P-Type Control
NOTES:
For Coaxitron
®
 controls, SW2 is not used; set all switches OFF.
For D-type control systems, refer to Table E.
Receiver Address
Switch Setting
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
1
OFF
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
OFF
4
ON
ON
OFF
OFF
OFF
5
OFF
OFF
ON
OFF
OFF
6
ON
OFF
ON
OFF
OFF
7
OFF
ON
ON
OFF
OFF
8
ON
ON
ON
OFF
OFF
9
OFF
OFF
OFF
ON
OFF
10
ON
OFF
OFF
ON
OFF
11
OFF
ON
OFF
ON
OFF
12
ON
ON
OFF
ON
OFF
13
OFF
OFF
ON
ON
OFF
14
ON
OFF
ON
ON
OFF
15
OFF
ON
ON
ON
OFF
16
ON
ON
ON
ON
OFF
17
OFF
OFF
OFF
OFF
ON
18
ON
OFF
OFF
OFF
ON
19
OFF
ON
OFF
OFF
ON
20
ON
ON
OFF
OFF
ON
21
OFF
OFF
ON
OFF
ON
22
ON
OFF
ON
OFF
ON
23
OFF
ON
ON
OFF
ON
24
ON
ON
ON
OFF
ON
25
OFF
OFF
OFF
ON
ON
26
ON
OFF
OFF
ON
ON
27
OFF
ON
OFF
ON
ON
28
ON
ON
OFF
ON
ON
29
OFF
OFF
ON
ON
ON
30
ON
OFF
ON
ON
ON
31
OFF
ON
ON
ON
ON
32
ON
ON
ON
ON
ON
Baud Rate
Switch Setting
SW2-6
SW2-7
SW2-8
2400
OFF
OFF
OFF
4800
ON
OFF
OFF
9600
OFF
ON
OFF