Справочник Пользователя для PASCO Specialty & Mfg. AC/DC Electronics Laboratory EM-8656

Скачать
Страница из 126
33
012-05892A
AC/DC Electronics Laboratory
®
slope (10 
Ω
) = ________ Volts/Amps
Optional
Replace the 10 
Ω
 resistor with the 100 
Ω
 resistor.
Click the “Increase Sweep Speed” button (
) in the Scope display to change the sensitivity
of the horizontal axis to 0.010 v/div.
Repeat the experiment. Record the new slope.
slope (100 
Ω
) = ________ Volts/Amps
Part B – Light Bulb Filament
PART I: Computer Setup for Light Bulb Filament
For this part of the activity you will use the filament of a light bulb as the resistor. In the Com-
puter Setup you will change the Amplitude and Frequency of the output AC waveform. You will
also change some of the settings on the Scope display.
Click the Signal Generator window to make it active.
Click on the Amplitude value to highlight it. Type in “2.5” as the new value. Press the “enter” key.