➤ Note: For quick reference, see the Experiment Notes window. To bring a display to the top,
click on its window or select the name of the display from the list at the end of the Display
menu. Change the Experiment Setup window by clicking on the “Zoom” box or the Restore
button in the upper right hand corner of that window.
The “Sampling Options…” for this experiment are: Periodic Samples = Fast at 1000 Hz and
Stop Condition = 4.00 seconds.
The Signal Generator is set to output 4.00 V, “positive only” square AC Waveform, at 0.40 Hz.
The “ON/OFF” button is set to “Auto” so the Signal Generator will start automatically when you
click MON (Monitor) or REC (Record) and stop automatically when you click STOP or
PAUSE.
The Graph is scaled between 0 and 5 V on the vertical axis (Voltage), and 0 to 4 seconds on the
horizontal axis (Time).
PART II: Sensor Calibration and Equipment Setup
You do not need to calibrate the Voltage Sensor or the Power Amplifier.
Place a 100 ohm (
Ω
) resistor (brown, black, brown) in the pair
of component springs nearest to the top banana jack at the lower
right corner of the AC/DC Electronics Lab Board.
Connect a 330 microfarad (
µ
F) capacitor between the compo-
nent spring on the left end of the 100 
Ω
 resistor and the compo-
nent spring closest to the bottom banana jack.
Put alligator clips on the Voltage Sensor banana plugs. Connect the
alligator clips to the wires at both ends of the 330 
µ
F capacitor.
Connect banana plug patch cords from the output of the Power
Amplifier to the banana jacks on the AC/DC Electronics Lab
Board.
Part III: Data Recording
Turn on the power switch on the back of the Power Amplifier.
Click the “REC” button (
) in the Experiment Setup
window to start recording data. The power amplifier output will
automatically start when data recording begins..
Data recording will continue for four seconds and then stop automatically.
Run #1 will appear in the Data list in the Experiment Setup window.
to Power Amp.
3 VOLTS MAX
C
W
Ω
AC/DC ELECTRONICS LABORATORY
KIT NO.
100 
Ω 
Res
300 
µ
F
 
Cap