11.2 Notification 
With the Notification function enabled, the switch can initiatively report to the management station 
about the important events that occur on the Views (e.g., the managed device is rebooted), which 
allows the management station to monitor and process the events in time. 
The notification information includes the following two types: 
Trap : Trap is the information that the managed device initiatively sends to the Network 
management station without request.   
Inform:Inform packet is sent to inform the management station and ask for the reply. The switch 
will resend the inform request if it doesn’t get the response from the management station during 
the Timeout interval, and it will terminate resending the inform request if the resending times reach 
the specified Retry times. The Inform type, employed on SNMPv2c and SNMPv3, has a higher 
security than the Trap type. 
On this page, you can configure the notification function of SNMP. 
Choose the menu SNMP→Notification→Notification to load the following page. 
 
Figure 11-8 Notification Config 
The following entries are displayed on this screen: 
¾
 
Create Notification 
IP Address: 
Enter the IP Address of the management Host. 
UDP Port: 
Enter the number of the UDP port used to send notifications. 
The UDP port functions with the IP address for the notification 
sending. The default is 162.   
User: 
Enter the User name of the management station. 
Security Model: 
Select the Security Model of the management station. 
Security Level: 
Select the Security Level for the SNMP v3 User. 
•  noAuthNoPriv: No authentication and no privacy security 
level are used. 
•  authNoPriv: Only the authentication security level is used.
•  authPriv: Both the authentication and the privacy security 
levels are used.