Инструкции По Установке для Panasonic Arbitrator 360
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
External GPIO Trigger Connection to G-Force Sensor (Option)
TGS-3DP
Pin #
Description
Cable Color
1
FLIP Out
White
2
RIGHT Out
Orange
3
LEFT Out
Blue
4
REAR Out
Red
5
FRONT Out
Brown
6
REC Out
Green
7
GND
Yellow
8
GND
Black
9
GND
Gray
If you have 5 trigger inputs available on Distribution
Center, connect Pin#1-5 with the center so that VPU can
start recording by the impact from any 6 directions with
indication on screen of Arb360FE and/or Control Panel.
Center, connect Pin#1-5 with the center so that VPU can
start recording by the impact from any 6 directions with
indication on screen of Arb360FE and/or Control Panel.
If you have only 1 trigger input available on Distribution
Center, connect Pin #6 to start recording by the trigger
regardless of which direction the impact comes from.
Center, connect Pin #6 to start recording by the trigger
regardless of which direction the impact comes from.
All GND(3 pins) should be connected.