Справочник Пользователя для Toro Marine Battery SA41

Скачать
Страница из 30
18
SA41 ELECTRICAL SPECIFICATIONS
INVERTER TYPE  PWM Full bridge power stage, with true sine wave AC output.
DEMAND START SECTION
Type:
Pulsing AC
Minimum Load Power to start (User adjustable):
3W to 20W
Maximum response time:
1 sec
Standby current from battery (Average): 
60mA
BATTERY VOLTAGE RANGE
Low DC Volts Disconnect (Instantaneous):
34V
Low DC Volts Cutout (Delayed, User Adjustable):
38-44V
Low DC Volts Cut-in (Delayed, User Adjustable):
44.4-52V
High DC Volts Cutout (Instantaneous, User Adjustable):
60-68V
High DC Volts Disconnect (Instantaneous):
70V
TOTAL APPLIANCE RATING AT
25°C
40°C 
Continuous:
3000W
2800W
30 Minute rating:
4700W
4400W
5 Minute rating:
5300W
1 Minute rating:
6500W
Surge rating:
8500W
INVERTER EFFICIENCY
Peak (at 500W):
91%
No load power consumption (C0NT mode):
0.66 A
MISCELLANEOUS SPECIFICATIONS
Output Frequency Accuracy:
50Hz ± 0.001 %
Output Voltage Accuracy (0 - 2200W)
240V ± 4 %
Total Harmonic Distortion (THD) 
< 4 %
Control Outputs 1 & 2, max DC sinking current:
50 mA
Alarm Inputs 1 & 2, input switching level:
HI  > 3 V
LO < 1 V
Operating temperature range:
-10°C to 50°C
Weight:
32 kg
DC Input is Electrically Isolated from AC Output
Note:  Through a policy of continued development, specifications are subject to change without
notice.
The above specifications are based on unity power factor.