Справочник Пользователя для Toshiba Oxygen Equipment LF620F

Скачать
Страница из 14
TIC-LF654L 
14 
Table 4.  Specification Code (Flange type detector LF654 Series) 
Model Specification 
Code 
Description 
Detector category 
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Gr.-A Gr.-B 
L  F  6  5   
 
 
 
 
 
 
 
Flange type electromagnetic flowmeter detector 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Usage 
cFMus Class 1 Division 2 Hazardous Location 
 
√ 
 
 
 
 
 
 
 
 
 
 
 
 
 
Meter size
 
 
 
 
 
 
  D 
 
 
 
 
 
 
½"(15mm)
√ 
 
     E 
      
1"(25mm)
√ 
 
     S 
      
1¼"(32mm)
√ 
 
     F 
      
1½"(40mm)
√ 
 
     G 
      
2"(50mm)
√ 
 
     W        
2½"(65mm)
√ 
 
     H 
      
3"(80mm)
√ 
 
     J 
      
4"(100mm)
√ 
 
 
 
 
  U 
 
 
 
 
 
 
5”(125mm)
√ 
 
 
 
 
  K 
      
6"(150mm)
√ 
     L 
      
8"(200mm)
√ 
 
 
 
 
  M 
 
 
 
 
 
 
10"(250mm)
√ 
 
 
 
 
  N 
 
 
 
 
 
 
12"(300mm)
√ 
 
 
 
 
  P 
 
 
 
 
 
 
14"(350mm)
√ 
 
 
 
 
  Q 
 
 
 
 
 
 
16"(400mm) 
√ 
√ 
 
 
 
 
  R 
 
 
 
 
 
 
18"(450mm)
√ 
             
Mounting 
Style(Note1)(Note6)
 
 
      L
      
Detector/Converter 
combined 
type
√ 
      M
      
Detector/Converter 
separate 
type 
√ 
√ 
      
      
Connection 
flange 
standard, 
Overall 
length
 
 
 
 
 
 
 
 
C   
 
 
 
 
ASME B 16.5 class 150, ISO length 
 
 
 
 
 
 
 
D   
 
 
 
 
ASME B 16.5 class 300, ISO length 
 
 
 
 
 
 
 
G   
 
 
 
 
EN 1092-1 PN 10, ISO length 
 
 
 
 
 
 
 
H   
 
 
 
 
EN 1092-1 PN 16, ISO length 
 
 
 
 
 
 
 
1   
 
 
 
 
ASME B  16.5 class 150, Toshiba length 
 
 
 
 
 
 
 
2   
 
 
 
 
ASME B 16.5 class 300, Toshiba length 
 
 
 
 
 
 
 
5   
 
 
 
 
EN 1092-1 PN 10, Toshiba length 
 
 
 
 
 
 
 
6   
 
 
 
 
EN 1092-1 PN 16, Toshiba length
 
 
 
Z      
Other (Note 2)
 
 
 
      
Electrode 
Material 
(Note 
3)(Note 4)
 
 
  B   
 
 
 
316L stainless steel  (Standard for PU, HR lining) 
 
 
   
 
 C     
Ti 
(titanium)
 
 
     
 D     
Pt-Ir 
(platinum/iridium)
 
   
 
 
 
 
  E   
 
 
 
Ta (tantalum)
 
   
 
 
 
 
  F   
 
 
 
Hastelloy C (Equivalent)  (Standard for PFA lining) 
 
      
      
Lining 
Materials 
(Note 
3)
 
 
 
 
 
 
 
 
 
  C   
 
 
PFA 
 
 
 
 
 
 
 
 
  N   
 
 
PU(Polyurethane) with NSF certified         
 
 
 
 
 
 
 
 
  E   
 
 
HR(Hard Rubber) with NSF certified
 
 
 
 
 
 
 
 
 
 
 
 
 
Grounding Ring Material (Note 3)(Note 4)
 
 
      
   C   
316 
stainless 
steel
 
      
   D   
316L 
stainless 
steel
 
      
   E   
Ti 
(titanium)
 
      
   F   
Ta 
(tantalum)
 
      
   G   
Pt-Ir 
(platinum/iridium)
 
      
   H   
Hastelloy 
(Equivalent)
 
 
 
 
 
 
 
 
 
 
 
 
 
Flow and calibration velocity range
 
 
 
 
 
 
 
 
 
 
 
  A   
1.0 to 32.8 ft/s (standard range calibration)
 
      
      
(Note 
5)
 
 
      
      
Excitation 
and 
Signal 
Cables
 
 
      
     A
not 
provided
 
 
 
 
 
 
 
 
 
 
 
 
 
Coating
 
 
      
      F
PU 
coating 
 
pearl-gray 
colored
 
 
 
 
 
 
 
 
 
 
 
 
  C
black tar epoxy resin 
 
Size code explanation: √ : Object      : Standard     : Option      –: Not available 
Note1:  In case of LF654 with cFMus approval, Cable glands are not provided. Refer to the part of “Cable connection port” at detector and converter. 
Note2: Connection flange standard EN 1092-1 PN10, EN 1092-1 PN 16,JIS B 2220 10K and JIS B 2220 20K are optional for both ISO length and Toshiba 
length.  
Note3:  Consult Toshiba before ordering when choosing materials at the wetting parts. 
Note4: In case of PU and HR lining with NSF approval, only 316/316L stainless steel are available, and Hastelloy C & Ti are undergoing testing. 
Note5: User specified range upon request, additional charges apply. 
Note6: Potting kit is available for submersible option when selecting Detector/Converter separate type with PU or HR lining.  Please consult Toshiba for 
details.