Important Installation Information
Electrical Power Supply
30'' Model:
4 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit 
36" Models:
6 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit
4 Burners with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15 
Amp circuit
48" Model:
6 Burners with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15 
Amp circuit
Gas Supply
Natural Gas 
6” water column (14.9 mb) min., 14” (34.9 mb) maximum
Propane Gas 
11” water column (27.4 mb) min., 14” (34.9 mb) maximum
All sealed burners are rated at 18,000 BTU/HR (*15,000 
BTU/HR on LP). *All models are convertible to LP/Propane 
gas using an accessory conversion kit.
IMPORTANT
When installing against a combustible surface, a Low Back 
guard is required. A THERMADOR
®
 Low Back guard must 
be purchased separately. See “Step 6: Backguard 
Installation” on page 13
 for backguard and installation 
information. 
When using the Flush Island Trim, THERMADOR 
recommends a minimum 12” (305 mm) rear clearance to a 
combustible surface (see Figure 1, Clearance 
Requirements
). Clearances from non-combustible 
materials are not part of the ANSI Z21.1 scope and are not 
certified by CSA. Clearances of less than 12” (305 mm) 
must be approved by the local codes and/or by the local 
authority having jurisdiction.
It is strongly recommended that this appliance be installed 
in conjunction with a suitable overhead vent hood (see 
“Step 1: Ventilation Requirements” on page 3). Due to the 
high heat capability of this unit, particular attention should 
be paid to the hood and duct work installation to assure it 
meets local building codes.
Check local building codes for the proper method of 
appliance installation. Local codes vary. Installation, 
electrical connections and grounding must comply with all 
applicable codes. In the absence of local codes the 
appliance should be installed in accordance with the 
National Electric Code ANSI Z223.1 current issue and 
National Gas Code ANSI/NFPA 70 – current issue. In 
Canada, installation must be in accordance with the CAN 
1-B149.1 and .2 – Installation Codes for Gas Burning 
Appliances and/or local codes. 
This appliance is equipped with an intermittent/interrupted 
ignition device that cycles the two far left surface burners 
on and off when in the ExtraLow
®
 setting. 
CAUTION: 
When connecting the unit to propane gas, make certain 
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator 
supplied with the rangetop. The maximum gas pressure 
to this appliance must not exceed 14.0” water column 
(34.9 mb) from the propane gas tank to the pressure 
regulator. 
CAUTION: 
This unit is designed as a cooking appliance. Based on 
safety considerations, never use it for warming or 
heating a room.
CAUTION: 
To eliminate risk of burns or fire caused by reaching over 
heated surface units, cabinet storage located above the 
surface units should be avoided.