APPENDIX
APPENDIX I: INPUT WIRING REQUIREMENTS
In p u t
P o w er In p u t
C u r r en t
S u g g e st ed S iz es ( S ee N o te s)
V o lta g e
F r e q .
3- P h
3- P h
F u se ( A m p s)
W ir e (A W G )
W ir e (C an ad a)
( V o lt s)
( H z )
( kV A )
( A m p s )
3- P h
3- P h
3- P h
200
50/60
34
98
110
A W G 2
2
208
50/60
34
95
110
A W G 2
2
220
50/60
34
89
100
A W G 2
2
230
50/60
34
85
100
A W G 4
2
380
50/60
34
51
60
A W G 6
6
415
50/60
34
47
60
A W G 8
6
460
50/60
34
42
50
A W G 8
6
506
50/60
34
40
45
A W G 8
6
575
50/60
34
34
40
A W G 8
6
Li n e V o l tages w i th S ugges ted C i r c ui t P r otec ti on an d W i r e S i z es
B as ed on N ati ona l E l ec tr i c C ode and C ana di an E l ec tr i c al C ode
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.