Sec tion 3 - De tailed Com po nents  De scrip tion
Re ceiver  Setup  and  Op er a tion
1. Place the re ceiver and an ten nas where there is a
clear line of sight to the area where the trans mit -
ter will be used. Ro tate the an ten nas to sep a rate
them by 90 de grees.
2. Con nect the power sup ply cord to the re ceiver. 
Plug the power sup ply into an AC out let. Turn
the re 
ceiver on and con 
firm that it is ON by
check ing the main dis play screen. 
Cau tion: Please make sure the AC power sup ply
is the cor rect volt age for your lo cal re quire ments 
be fore it is plugged into the wall.
3. Man ual  Chan nel  Change.  Press the SET but -
ton and the Group num ber will start to flash.
The Up and DOWN but tons al low you to scroll
through the fac tory set group. When the group
you de sire is dis played, press SET to se lect that
group and the Chan nel Num ber will start flash -
ing. Scroll to the de sired chan nel and press SET
to se lect. The num bers will stop flash ing and the 
new group and chan nel are in stalled.
4. Fre quency  As sign ment  (Out side  of  pre set
Groups and Chan nels), press SET and UP at
the same time and the group and chan nel will go 
blank and the Fre quency will start flash ing. Use
UP/DOWN to scroll in 25 KHz steps to the de -
sired fre 
quency. Press SET and the fre 
quency
will be se lected and stop flash ing. Press Set and
UP at the same time to re turn to group and chan -
nel op er a tion. Hint: hold ing in the Up or Down
key will in crease the speed of the scroll. Just re -
lease and press again for fine con trol.
5. Ad vanced  ClearScan:
  
This  fea ture  au to mates
the pro cess of find ing a clear group of
inter-mod u la tion free chan nels and the clear est
chan nels within those groups. 
a.
ClearScan
 
for Groups: From the main dis 
-
play screen, push SET once and the Group
Num ber will flash. While Group is flash ing,
press and hold SET un til ClearScan ap pears,
re 
lease the set key. When the scan is com 
-
pleted, the dis play will show the group with
the most clear chan nels and the Chan nel num -
ber will in di cate how many clear chan nels are
in that group. Use the UP/DOWN keys and to
view other groups and press SET to se lect a
group. The Group will be set and the Chan nel
will start to flash. Se lect a chan nel man u ally
or use ClearScan for Chan nels.
ClearScan for Chan 
nels: To scan for the
clear est chan nel in a group, press and hold set
while the Chan nel is flash ing un til ClearScan
ap 
pears, re 
lease the SET but 
ton. When the
scan is com 
plete, the dis 
play will show the
clear est avail able chan nel. Use UP/DOWN to
scroll through the other avail 
able chan 
nels
rank from clear est to least clear (but still avail -
able for use, ClearScan will not dis play any
chan nel that can't be used). Press SET to se -
lect the chan nel.
b.
c.
Auto ClearScan: This func tion will find the
clear est group and chan nel with the press of
just one but ton. With noth ing flash ing, press
and hold the SET but ton un til ClearScan ap -
pears on the right side of the screen. When the 
scan is com plete, the re ceiver will be set to the 
clear est chan nel in the clear est group.
d.
ClearScan Band: While in the Fre 
quency
Mode, this func tion will scan the en tire band
look ing for the clear est fre quency, re gard less
of groups and chan nels. In Fre quency Mode,
press Set once and the fre quency will flash,
press and hold set until ClearScan ap pears on
the right side of the dis 
play. The scan will
con tinue un til you press Set again so you can
scan a lo ca tion over night, 24 hrs, a week, or a
few sec onds. When you press Set again, the
scan will stop and the clear est fre quency will
be dis 
played. You can scroll through the 8
clear est fre quen cies us ing the Up and Down
but tons. Press Set to ac cept the fre quency dis -
played.
-2-
Antenna
High
Z
Line
Level
Mic
Line
Telex Communications, Inc.       Made in U.S.A.
12-15V
AC/DC
+
-
U.S. Patent No. 6,256,484
Balanced
Audio
FMR-500
BAND A
Tested to Comply
with FCC Standards
CANADA
S.N. 1059
Telex
R
8 5
7
6
4
Fig ure 2 - FMR-500 Back Panel
GPA CH
12u 05
-20 -10 -6  -
 
3   0  +3
1   3  10   30   100
E V
AU DIO
set
power
Telex
R
CLEAR
SCAN
TM
FMR-500
3
3
2
1
Fig ure 1 - FMR-500 Front Panel
Antenna
High
Z
Line
Level
Mic
Line
Telex Communications, Inc.       Made in U.S.A.
12-15V
AC/DC
+
-
U.S. Patent No. 6,256,48
Balanced
Audio
90
FMR-500
BAND A
Tested to Comply
with FCC Standards
CANADA
S.N. 1059
Telex
R
Proper An tenna Orientation
FMR-500  Re ceiver  Con trols,  Con nec tors,  and  In di ca tors
1.
Power ON/OFF
2.
Graph i cal  Dis play
a.
Chan nel  Dis play
b.
Fre quency
c.
Bat tery  Strength
In di ca tor
d.
Di ver sity  In di ca tor
e.
RF Strength of
Sig nal  In di ca tor
f.
Au dio  Level  In di ca tor
g.
Gui tar  Mode  In di ca tor
3.
Dis play  Con trol  But tons  (Set/Up/Down)
4.
Power  Con nec tor
5.
XLR  BalancedMic/Line Level
Au dio Out put Line Level Ad just able
6.
Un bal anced Line Level Au dio Out put
Con nec tor  with  Level  Ad just ment
7.
TNC  An tenna  In put  Con nec tors
8.
Power Cord Re tainer