THERMOSTAT
WIRE TERMINAL
 
 
Figure 41 
Thermostat terminal 
OPERATING THE STOVE USING A THERMOSTAT 
 
A thermostat will help you maintain a constant house temperature 
automatically. A millivolt  or 24 Volt thermostat is required. A fixed wall 
mount or remote model can be used. 
THERMOSTAT INSTALLATION 
 
• 
Unplug the stove from the power outlet. 
• 
Connect two thermostat wires to the terminal block located on the 
lower right side of the back of the stove. To do so, loosen the two 
screws and insert the wires in the terminals. Tighten the two screws. 
(See Figure 41) 
• 
If you are using a wireless wall thermostat or a hand held thermostatic 
remote control, you can locate the receiver behind the stove’s back 
panel, on the right side, just below the terminal block.  Most receivers 
are already equipped with quick-connect terminals.  Simply unplug the 
PC board wires connected to the back of the terminal block and 
connect them directly with the receiver’s terminals.   Location of the 
thermostat is very important to obtain the best comfort and efficiency 
from you HYBRID-35.  The thermostat should be mounted 50 inch 
from the floor on a wall located 15 to 20  feet from the stove.  You 
should avoid installing directly in front of the stove to avoid 
cycling.(See Figure 42) 
MODES 
 
THERMOSTATIC MODE 
• 
To engage this mode, the thermostat icon 
 
must be pushed 
upon starting the stove. The heat setting is then selected using the 
“Heat Level” selector. When set in thermostatic mode, the stove will 
automatically run at the heat level selected until the set room 
temperature is reached. When that occurs, the stove will switch to 
heat setting #1 (lowest) until the thermostat calls for heat again.  The 
convection blowers will also slow down to low  speed. When the 
thermostat calls for heat again, the stove will automatically switch 
back to the selected heat level. 
 
• 
N.B.:  If the room temperature remains stable and the thermostat 
does not call for heat during at least 45 minutes, the stove will shut 
down.  When the thermostat calls for heat again, the stove will start an 
ignition cycle.  Once the ignition cycle is completed, the stove will 
increase its feed rate to match the heat selected heat level. 
 
 
NOTE: When in  thermostatic mode: 
 
• 
You should not operate the manual control or play with the 
temperature setting. 
 
• 
YOUR THERMOSTAT SHOULD BE INSTALLED BY AN 
AUTHORIZED DEALER OR QUALIFIED TECHNICIAN. 
 
D = MINIMUM DISTANCE 15 FEET
SHOULD BE AVOIDED
 
 
Figure 42 
Thermostat location 
 
 
 
 
 