TROUBLESHOOTING 
When your stove acts abnormally, the first reaction is to get help. This guide may save you time and money by enabling you to resolve simple problems 
yourself. Problems can be caused by: 1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You 
can usually solve problems related to 1 and 2. Your dealer can solve problems related to 3, 4 and 5.  Refer to ELECTRICAL DIAGRAM and 
REPLACEMENT PARTS section to help identify and locate stove parts. 
 
STOVE SHUTS OFF AND SHOWS ERROR CODE “P” 
 
 
Possible Causes:
Possible Remedies: (Unplug stove first when possible) 
 
1. 
Airflow  pressure switch hose or hose connector tip are blocked. 
 
Pull out air hose from the airflow switch and blow through it.  If air flows 
freely, the hose and tube are fine.  If air will not flow throw the hose, use a 
thin wire to clear the blockage.  If the problem occurs again shortly after , 
you may have to remove accumulation on the pressure switch probe 
located inside of exhaust blower housing(refer to maintenance section) 
 
 
2. 
The air inlet, burn pot, interior combustion air chambers, combustion 
blower, or exhaust pipe are blocked with ash or foreign material. 
 
 
Follow all cleaning procedures in the maintenance section of the owner’s 
manual. 
 
 
3. 
Vent pipe is incorrectly installed. 
 
 
Check to make sure vent pipe installation meets criteria in owner’s manual 
and pipe manufacturer’s recommendations. 
 
 
4. 
The pressure switch connections are faulty. 
 
 
Check the connectors that attach to the pressure switch. 
 
 
5. 
The pressure switch wires are pulled loose from the connectors on 
the wiring harness. 
 
 
Check to see if the wires are loose at the connector. 
 
6. 
Combustion/exhaust blower failure. 
 
This blower must come on when you start the unit.  If it does not, make 
sure there is power on the connections, if so, the motor is likely to be 
defective; if not refer to #7 
 
 
7. 
Control board not sending power to combustion/exhaust blower. 
 
 
If there is no power going to the combustion blower, check all connections.  
If all wires are properly connected, you have a bad control board. 
 
 
8. 
Control board not sending power to pressure switch. 
 
 
There should be 120-volt going through the pressure switch when the 
stove is on. You will need a technician to perform this test. 
 
 
9. 
Airflow pressure switch has failed (very rare). 
 
To test the airflow pressure switch, you will need to disconnect the air hose 
from the blower casing.  With the other end still attached to the switch, 
very gently suck on the loose end of the hose (you may want to remove 
the hose entirely off the stove and the switch first and make sure it is 
clear).  If you hear a click, the switch is working.  BE CAREFUL, TOO 
MUCH VACUUM CAN DAMAGE THE SWITCH. 
 
 
 
 
 
 
 
 
 
 
27