FREESTANDING INSTALLATION 
 
SI
D
E
 W
A
L
L
6"
BACK WALL
2" *
3"
 
Figure 1 
Back wall installation 
 
 
2"
3"
3"
2"
ADJACENT WALL
AD
JA
CENT
 W
A
LL
 
Figure 2 
Corner installation 
 
HYBRID-35 FREESTANDING PELLET STOVE 
 
Width: 22 1/2”  
Height: 29” 
Depth: 24 1/2” 
Weight: 195 lbs. 
Flue size: 3” or 4” 
Hopper Capacity: Up to 35 lbs. 
(This can vary slightly depending on pellet size, length, and diameter) 
EPA status: exempt 
Burn rate: 1 lb. to 4.0 lbs. per hour 
BTU range: 8,200 to 35000 
Electrical consumption:  3.5 Amps lighting cycle 
                                       2.5 Amps. continuous duty 
Control board fuses:  Main: 7.5A-250V fastblow 
                                   Igniter: 5A-250V fastblow 
Electrical requirement: 120VAC 15A 
Approved installations: mobile home, conventional 
 
PREPARATION 
 
Factory packaging must be removed, and some minor assembly work is 
required prior to installation: 
 
• 
The door overlay must be installed on the door frame; 
• 
The louver kit must be installed in front of the heat exchanger. 
 
NOTE: Normally, your dealer will perform these functions. 
 
To remove ashes, use the ash pan or a vacuum cleaner.  If you want to 
use the ash pan, you will have to remove the plate located at the right side 
of the burn pot.   
 
1-  Remove the three screws 
2-  Remove the plate 
3-  Put the three screws back 
4-  Use the ash dump cap provided with the stove 
CLEARANCES 
 
The HYBRID-35 has been tested and listed for installation in regular and 
mobile homes.(refer figure 1 & 2) 
FLOOR PROTECTION:  minimum 6” in the front and 6” on each side. The 
stove must be placed on a continuous (grouted joints) non-combustible 
material such as ceramic tile, cement board, brick, 3/8” millboard or 
equivalent, or other approved or listed material suited for floor protection. 
NOTE: ceramic tile, or any tile, must be laid on a continuous non 
combustible sheet to prevent the possibility of embers falling through to the 
combustible floor if cracks or separation should occur in the finished 
surface, this also applies to floor protection for Built-in raised hearths. 
Check local codes for approved alternatives. 
Clearances are measured from the sides, back and face (door opening) or 
stove body (refer to fig. 3).  
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE 
INSTALLATION OF THIS UNIT. 
 
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT 
MANUFACTURER.
 
 
6"
6"
6"
 
Figure 3 
Floor protection