If the unit is setup as an RPM monitor then following steps are performed for setting up various parameters: 
FUNCTION
DISPLAY SHOWS
TO CHANGE
 
Filter 
value 
   1,2,4,6,10,15,20,30,60  
Push 
^v key to obtain desired value 
 
Decimal point        
  
 
dP  9999          
 
 
Push ^v key to 
placement             
 
   
dP  999.9         
 
 
move decimal 
                      
 
 
    
dP  99.99         
 
 
point to desired 
                     
 
 
   
dP   9.999        
 
 
position. 
 
Scaler               
 
 
'SCALER' followed by preset scaler 
Push ^v key to increment or decrement 
                     
 
 
value e.g. 10.00024 with active digit 
active digit. Push <NXT> key to change 
                     
 
 
flashing.          
 
 
 
active digit. 
 
Division Factor     
 
'DIV FAC' followed by preset division 
 Push ^v key to increment or decrement 
                    
 
 
 
 
by preset division  factor( e.g. 12`   
 active digit. Push   <NXT> key to   
 
 
 
 
with active digit flashing).  
  
change active digit. 
 
 
Limit 1    
 
 
'CH1 LT1' followed by preset Limit 1 
Push ^v key to increment or decrement 
Limit 
   value 
e.g. 
123.4 with active digit      
active digit. Push  <NXT> key to  
Limit 
   flashing. 
    active 
digit. 
   
    For 
limits 
&3 
CH1 LT2CH1  LT3  
NOTE:   Limit3 is audio visual alarm only 
 
 
    
 
followed by limit  value.   
 
--- it has no relay output.  
 
 
 
Relay deadband   
 
'dEAdbd' followed by   deadband   
Push ^v key to increment or decrement 
                     
 
 
value e.g. 0002 
   active 
digit. 
Push 
 
<NXT> key to make 
 
 
 
 
 
 
 
 
 
next digit active. 
 
Latching or non -  
 
'LATCH' for latching mode. 
 
Push ^v  key  to obtain  alternate mode. 
latching relay setup.  
 
'NON  LCH' for non   latching  mode. 
 
 
 
 
 
Limit outputs prog- 
 
LT1 N.O. or LT1 N.C 
 
 
Use ^v key to obtain 
rammed as normally 
 
LT2 N.O. or LT2 N.C 
  alternate 
mode. 
open or closed 
 
 
LT3 N.O. or LT2 N.C 
 
 
 
ALARM OUTPUTS: 
 
Status: 
The system has optional process alarm outputs that are activated when limit is exceeded on any of the two channels. The alarms 
can be programmed as normally open or normally closed (see SETUP) and latching or non-latching. The status of these alarms is 
indicated on the front panel by LEDs. When ever an alarm is activated the respective LED is turned on. Each channel has two 
outputs (relay or open collector) and one audio visual alarm. Audio visual alarm provides a visual indication on the front panel 
(LED) and a buzzer output if a programmed limit value is exceeded. Buzzer can be turned off, if so desired (look under SETUP). 
 
Resetting: 
 
Once energized, alarms can be reset in two different ways --- automatically or manually (non latching or latching). In non-
latching mode, the alarm outputs will de-energize on their own when process variable drops below the limit value. In latching 
mode, they stay energized even if the process variable drops below the limit. To reset the energized outputs in the latching mode, 
first make the display indicate the limit that needs to be reset (e.g. "CH1   LT2"), by pushing the DATA key. Next, keeping the 
DATA key pushed while limit value is displayed, go on to push the RESET key. The respective alarm output will de-energize 
and the system will indicate so by displaying RLY RST.