Cycle Time Settings
Section 5-6
System Setup
Constant Cycle Time Exceeded Flag
Constant Cycle Time Exceeded Error Clear Bit
Constant Cycle Time 
Function in Sync 
Mode
When in Sync Mode with a Sync Cycle Time set for the Coordinator Module
cycle time (default), and the constant cycle time function is used, the cycle
time for Motion Control Modules will be as described below.
Constant Cycle Time 
Function Enabled for 
Coordinator Module
The Motion Control Module cycle time is synchronized with the Coordinator
Module constant cycle time, and will therefore be constant.
Constant Cycle Time 
Function Enabled for 
Motion Control Module
The Motion Control Module cycle time is synchronized with the Coordinator
Module constant cycle time, and gradually is made constant, while the Motion
Control Module's built-in I/O refresh timing is made constant.
The time from when the processing starts in the Motion Control Module until
the I/O refresh will be constant.
Constant cycle time (enabled)
Constant cycle time
Constant cycle time
Real time
Real time
Real time
Tab page
Name
Settings
Default
Timer/Peripheral servicing or 
Cycle Time 
Cycle Time
0.1 to 100.0 ms, 
0.1 ms units
Variable
Name
Address
Description
Constant Cycle Time 
Exceeded Flag
A404.05
This flag turns ON when the constant cycle 
time function is used and the cycle time 
exceeds the constant cycle time set value.
Name
Address
Description
Constant Cycle Time 
Exceeded Error 
Clear Bit
A509.15
The constant cycle time function can be 
enabled again after the cycle time has 
exceeded the constant cycle time and A404.05 
has turned ON.
Coordinator 
Module
Motion 
Control 
Module
Constant cycle time
Processing
Constant cycle time
Processing
I/O refresh
I/O refresh
Waiting to 
synchronize
Waiting to 
synchronize