Справочник Пользователя для New Buck Corporation 81

Скачать
Страница из 39
INSTALLATION PROCEDURE 
       
 
(Use a chimney connector or a  Listed Direct or Positive Connect) (See Page 8.) 
POSITIONING HEATER 
 
When positioning  heater, the following conditions 
MUST be met! (See Figure 2). 
 
1.  The front of damper opening must be positioned 
BEHIND rear edge of lintel to ensure proper draft. 
(See Figure 2). 
 
2.    Center heater in the fireplace opening. 
 
 
 
 
 
 
 
 
 
MOUNTING TRIM PANELS 
 
 
After unit is positioned, mark mounting position of  trim 
panels as follows: 
 
1.  Place side trim panels flat against face of fireplace.  
Mark front edge of trim panel with a pencil to make a 
vertical reference line. (See Figure 3). 
2.  Place top (long) trim panel on top of  unit.  
The  panel should be flat against the outside face 
of  fireplace and standing vertically.  Mark along  
lower edge of trim panel with a 
 
pencil to make a 
reference line for mounting. 
     
 
3.  Slide unit out of fireplace far enough to work  
        behind trim panel reference lines. 
FIGURE  3         MOUNTING TRIM  PANELS 
FIGURE  2          POSITIONING 
4.    Mount side trim panels. (See Figure 3).  
a. Position side trim panel on reference line. 
b. Drill mounting holes in center of  side trim panel mounting brackets to allow for adjustment in and out if  
necessary. 
c. Mount trim panel using self-tapping screws provided. 
5.  Place top trim panel on reference mark. Top trim panel mounting bracket (supplied) must overlap rear lip of 
top trim panel.  Drill mounting holes in top of stove using holes in bracket as guide.  Tighten  screws.  
6.  Follow installation procedures in listed direct connect or positive connect kit you are using and install heater  
and  connect  kit in fireplace.  If not using one of installation methods shown on Page 8, continue.  
7.  Slide unit back into fireplace.  Check to be sure that trim panels are properly positioned and lie flat against  
front of fireplace.  If one or more of panels is out of position, slide unit out and reset by loosening mounting 
screws and repositioning in slot. 
8.  Reinstall top trim panel by sliding rear lip of top trim panel underneath front lip of mounting bracket already 
secured to top of unit. 
 
SIDE TRIM PANEL 
 
TOP TRIM PANEL 
TOP TRIM PANEL 
MOUNTING BRACKET 
FIRE PLACE CUT AWAY 
VERTICAL PLANE 
LINTEL EDGE 
DAMPER 
OPENING 
Page 9