SECTION III 
PRE-FAB INSERT INSTALLATION 
 
The Model 81 may be installed into any UL listed pre-fabricated fireplace that is large enough 
to accept it. 
 
NOTE: 
When installing Model 81 into a Pre-Fab Zero-Clearance fireplace, a UL-1777 
LINER must be installed the Full Length of chimney and attached to flue exit of insert.   
 
NOTE:  The ash lip, smoke baffle and smoke shelf of pre-fab fireplace may be  removed if 
necessary to provide room for these models.  Any other alteration to unit will void ALL New 
Buck Corporation  responsibility and liability.  The warning label below must be attached to 
back of fireplace. 
 
NOTE:  Plug power cord into a 115V AC outlet.  Set switch to “Manual” and rheostat to 
“High” position to ensure motor operates properly.  Route power cord to prevent damage to 
cord insulation from heat and sharp objects.  Keep cord out of way of traffic to  prevent damage 
caused by tripping, etc.  
 
 
NOTE:  DO NOT BLOCK ANY EXISTING LOUVERS OR VENTS ON EXISTING  
               PRE-FAB WITH ANY TRIM PANELS FOR  MODEL 81. 
 
Except  for “NOTES” above, please follow instruction of masonry installation,  Section II. 
 
Instruction 
Minimum clearances for stove 
Minimum clearances for floor protector 
 
 
 
 
 
 
 
 
 
 
WARNING:  
This fireplace must be 
restored to it’s original condition for safe use 
if the fireplace insert is removed. 