5.  Next, remove the four (4) screws holding the heater  to  the stand.  Position heater out of the 
way of the installation area. 
 
6.  Check that the pedestal stand is still aligned with the marks and now, mark the  outside air 
opening of the stand on the pad. 
 
7.   Next, mark the center line of the outside air opening.   Set stand aside for now. 
 
8.   Next,  cut a 4 1/4" diameter hole in the  pad  and  continue through  the  floor.   
 
CAUTION 
 
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR MUST BE 
MAINTAINED. (MOVE OPENING AND/OR REPOSITION HEATER LOCATION IF 
NECESSARY.)  
 
9.  Now, reposition the pedestal stand and set on the  pad  being sure to line the stand up with 
the reference marks. 
 
10. Using an electric drill and 3/8" masonry bit, drill four  (4) holes  in the protective pad using 
the holes in the  bottom  side lips of the pedestal stand as a guide.  Be careful to drill  only 
through the pad and not into the floor.  Change the bit to a 1/4" metal bit and drill through 
the floor. 
 
11. Using four (4) 3/8" x 1-1/2" lag bolts,  secure the  pedestal  stand  and pad to the floor 
of  the  mobile  home. 
   
CAUTION 
 
IF  A THICK FLOOR PROTECTOR IS USED, YOU MAY HAVE TO  USE  LONGER 
LAG BOLTS. 
 
12. Set  the heater back onto the stand and resecure  using  the screws. 
 
13. Obtain the outside air duct from the box in the pedestal  kit marked FA P21B.  
 
14. From  under the mobile home, slip the duct up through the  4-1/4"  hole.  Push up until the     
face of the outside air duct  contacts the underside of the floor of the mobile home.  For 
certain floor  thickness,  you may have to shorten the  length  of  the outside air duct. 
 
15. Secure the outside air duct to the floor using the four  (4) #10 x 1" screws provided.    See 
Figure 12. 
 
26