Chapter 2
Function Reference — AI_Configure
NI-DAQ FRM for PC Compatibles
2-6
©
 National Instruments Corporation
AI_Configure
Format
status = AI_Configure (deviceNumber, chan, inputMode, inputRange, polarity, driveAIS)
Purpose
Informs NI-DAQ of the input mode (single-ended or differential), input range, and input 
polarity selected for the device. Use this function if you have changed the jumpers affecting 
the analog input configuration from their factory settings. For devices that have no jumpers 
for analog input configuration, this function programs the device for the settings you want.
Parameters
Input    
Parameter Discussion
chan is the analog input channel to be configured. Except for the E Series devices, 
the AT-MIO-64F-5, and the AT-MIO-16X, you must set chan to –1 because the same analog 
input configuration applies to all of the channels. For the E Series devices, AT-MIO-64F-5, 
and AT-MIO-16X, chan specifies the channel to be configured. If you want all of the channels 
to be configured identically, set chan to –1. 
Range:
See Table B-1 in Appendix B
.
inputMode indicates whether the analog input channels are configured for single-ended or 
differential operation:
0:
Differential (DIFF) configuration (default).
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
chan
i16
channel to be configured
inputMode
i16
indicates whether channels are configured for 
single-ended or differential operation
inputRange
i16
voltage range of the analog input channels
polarity
i16
indicates whether the ADC is configured for 
unipolar or bipolar operation
driveAIS
i16
indicates whether to drive AISENSE to onboard 
ground