Chapter 2
Function Reference — WFM_ClockRate
NI-DAQ FRM for PC Compatibles
2-406
©
 National Instruments Corporation
WFM_ClockRate
Format
status = WFM_ClockRate (deviceNumber, group, whichclock, timebase, interval, mode)
Purpose
Sets an update rate and a delay rate for a group of analog output channels.
Parameters
Input   
Parameter Discussion
group is the group of analog output channels (see 
WFM_Group_Setup
).
Range:
1 for most devices.
1 or 2 for the AT-AO-6/10.
whichclock indicates the type of clock:
0:
The update clock (default).
1:
The delay clock.
2:
The delay clock prescalar 1 (E Series devices only).
3:
The delay clock prescalar 2 (E Series devices only).
Notice that you can program the delay clock only on the AT-MIO-16X, AT-MIO-64F-5, 
and E Series devices.
timebase is the timebase, or resolution, NI-DAQ uses in determining intervaltimebase has 
the following possible values:
–4:
40 MHz clock used as a timebase (25ns) (DAQArb 5411 only).
–3:
20 MHz clock used as a timebase (50 ns) (E Series only).
–1:
5 MHz clock used as timebase (200 ns resolution) (AT-MIO-16F-5, 
AT-MIO-64F-5, and AT-MIO-16X only)
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
group
i16
group of analog output channels
whichclock
i16
the update or delay clock
timebase
i16
resolution
interval
u32
timebase divisor
mode
i16
enables the delay clock