Digital I/O Functionality
This chapter describes the primary functions of the digital inputs and 
outputs on the NI 1450 Series Compact Vision System. This chapter also 
includes guidelines for connecting the digital I/O and for setting up a 
typical NI 1450 system.
Overview
The digital I/O functions are accessible through 2 TTL inputs, 10 TTL 
outputs, 13 isolated inputs, and 4 isolated outputs.
Input signals can be used as triggers, product selection ports, to read 
quadrature encoders, or they can be user-defined. Uses for output signals 
include controlling camera reset and exposure, controlling strobe lighting, 
outputting inspection results, communicating with PLCs, or they can be 
user defined. 
For information about how to use LabVIEW RT to implement specific 
digital I/O functions, refer to the application software documentation and 
examples in the following locations:
Program
 
Files\National
 
Instruments\NI
 
1450
 
Series\Docs
Program
 
Files\National
 
Instruments\LabVIEW
 
7.0\
examples\NI
 
1450
The NI 1450 Series Compact Vision System Digital I/O Help is available 
for each example. This help file contains digital I/O reference information 
and instructions for using the LabVIEW FPGA VIs.
Tip