Chapter 4
Using the MPC
the menu is changed to ‘YES’, then the IP, SUBNET and GATEWAY rows will be assigned 
automatically upon activation.
Connect an RJ45 cable from your local internet or intranet wall jack to the Ethernet port on the MPC.
You may receive an IP address or a “static” IP location on your internal network (intranet) given by 
your Network Administrator to use as a URL. An IP location associates an IP address with a name, for 
example “MPC1”, in your Domain Name Server (DNS).
Open your internet browser and connect to the internet on a PC. In the Address field of your internet 
browser, type in the IP address or static IP location to go to the Modulated Precision Clock website for 
your MPC. The following URLs are fictional examples:
http://123.123.123.123/
http://mpc1/
You can monitor your connection status in the Connect menu described in Section 5.2.2, Connect on 
Page 44
.
Details on the Modulated Precision Clock website login and features can be found in Section 6.1 
starting on Page 49.
4.2.2
Modem or Direct Connect (PPP) Client
Use the Configure Modem menus as described in Section 5.2.5, Configure Modem on Page 47 or the 
Configure Direct menu as described in Section 5.2.6, Configure Direct (PPP) on Page 48 to set up the 
modem direct connection. Then decide whether or not the IP address is assigned automatically for the 
MPC. If AUTO IP in the CONFIG MODEM or CONFIG DIRECT menu is changed to ‘YES’, then 
the IP row will be assigned automatically upon activation.
Connect an RJ11 cable from a phone jack to the Modem port on the MPC, or an RS232 cable from the 
PPP port on the MPC to a COM port on your PC.
In order to install a modem or PPP connection for your PC follow the rest of this section.
On your PC select Start | Settings | Control Panel from the taskbar and click on the Modems icon as 
seen in Figure 6.
 Figure 6: Modems Icon