Справочник Пользователя для MPC OM-20000072

Скачать
Страница из 102
52
MPC User Manual Rev 0D
Chapter 6
Software Programs
 Table 2:  UDP Message Format
Next, choose when to send the data or set up a schedule. Choosing CONTINUOUS logs your data 
continuously. It will start a new file every hour that is divisible by the Rollover amount in the Choose 
Where section. The other choices are Everyday, Weekdays, Weekends, and Only Today. If you select 
any of these choices, you can then enter a UTC start time in hours in the Start Time field and the 
amount of hours to continue logging in the Duration field. The start time refers to the start of the day.
Finally, type in the logs you want in this schedule in the Choose What section’s edit box. Ensure each 
log request is on a new line. For more information on the available logs for the OEM4 family of 
receivers, please refer to Volume 2 of the OEM4 Users’ Guide.
Click on the Submit button when you have completed your schedule list. The Command/Response 
Summary for your schedule will appear. An example is shown in Figure 47 on Page 53. If you 
misspell any of the logs, the Command/Response window will contain syntax errors for you to check.
Click on the Cancel button to return you to the main Logging Control window (Figure 45 on 
Page 50
).
Filename Examples:
If it is 3 p.m. and you request CONTINUOUS in the Choose When section, and 6 in the Choose 
Where section’s Rollover field, 
hh
 will be 12 and will roll over at 6 p.m. (only 3 hours later) when 
hh
 
will be 18. The next rollover will be at midnight (6 hours later) when 
hh
 will be 00.
Here are some filename examples starting at 5:45 p.m., the First Letters of File Name were entered as 
‘range’, with a rollover of 6 hours:
range02011712.bin
range02011718.bin
range02011700.bin
range02011806.bin
range02011812.bin
* 1. The MPC internal time is Coordinated Universal Time (UTC) and may vary by several hours 
from your local time.
2. If you have any difficulty with sending files, for instance e-mail or external ftp, NovAtel 
Customer Service may request any GPSServer.log or LoggerServer.log files from your MPC’s 
ftp site or root directory.
Description
Offset
Size
Type
Value          
Sync1
0
1
uchar
0xAA
Sync2
1
1
uchar
0x44
Sync3
2
1
uchar
0x16
MPCID
3
4
ulong
0....MAX_ULONG (unique MPC station ID, 
see Section 6.1.2.1, Set MPC Name on Page 56)
Hop Count
7
1
uchar 
0...255 (the number of times the UDP was 
forwarded between NovAtel relay stations)
Message Length
8
2
ushort
0...65535 (size of the imbedded message but not 
including the header)
Message
10
<65535
binary
NovAtel OEM4 ASCII or binary message