PROBLEM
POSSIBLE CAUSE
SOLUTIONS
STOVE SMOKES 
Operating Technique 
Fully open the primary air control one minute before opening doors. 
 
Cold Chimney 
Preheat the chimney when first starting a fire. 
 
Blocked Chimney 
Examine the chimney and stovepipe for blockage or creosote 
accumulations. 
 
Oversized Chimney 
Reline the chimney to the appropriate diameter 
 
Undersized Chimney 
Install a draft inducer or replace the chimney. 
 
Chimney Too Short 
Lengthen the chimney. 
 
Air Infiltration Into The 
Chimney 
Seal chimney connections and openings in clean-out doors. 
 
More Than One Appliance 
Connected to the Flue 
Disconnect all other appliances and seal openings. 
BACK-PUFFING OR 
GAS EXPLOSIONS 
Operating Technique 
Fully open the primary air control one minute before opening the 
door and keep it fully open for a few minutes after reloading. 
 
Extra Low Burn Rate 
Burn the Fireplace Insert at a higher burn rate. 
 
Chimney Down-draft 
Install a chimney cap. 
 
Excessive Ash Build-up 
Empty ashes more frequently. 
UNCONTROLLED 
OR SHORT BURN 
Unsealed or Open Door 
 
Close the door tightly or replace the gaskets. 
 
Excessive Draft 
Check the installation. Operate at LOW BURN. Install stovepipe 
damper. 
 
Deteriorated Cement Seals 
Reseal the Fireplace Insert with furnace cement. 
 
Extra Long Chimney 
Shorten the chimney.  Install stovepipe damper. 
 
Oversized Chimney 
Reline the chimney to the proper diameter. 
 
High Winds or Hilltop 
Location: 
Install a chimney cap. 
 
 
Excessive Draft 
Draft in excess of 0.1 wc should be corrected with a stovepipe 
damper 
INSUFFICIENT HEAT  Poor Quality or Green 
Wood 
Use only air-dried wood, preferably dried at least one year. 
 
Low Burn Rate 
Operate the Fireplace Insert at a higher burn rate. 
 
Air Insulated Chimney 
Replace with a pre-fabricated insulated chimney system or a 
properly sized masonry chimney. 
 
Cold Exterior Chimney 
Reline or insulate the chimney. 
 Leaky 
Stovepipe 
or 
Chimney 
Check the installation. 
 
Too Much Heat Loss From 
House 
Caulk windows, seal openings in home. 
BLISTERING OF 
ENAMEL CASTING 
Operating Technique 
Do not over-fire the Fireplace Insert.  Monitor Fireplace Insert 
temperatures. Use seasoned wood only. 
 
Excessive Draft 
Check the DRAFT.   A damper may be required.  Operate the 
Fireplace Insert at a LOW BURN range.