MODEL 110 AUTORANGING DIGITAL MULTIMETER 
 
 
5.2  DC Voltage Measurements 
 
WARNING 
Maximum Input Voltage is 600VDC. To avoid electrical shock hazard and/or 
damage to this instrument, do not attempt to make any voltage measurement that 
may exceed this limit. 
 
1.  Connect the red test lead to the 
‘V’
 jack 
and the black test lead to the 
‘COM’
 jack.   
2.  Set the Function Selector switch to the   
V    range. 
3.  Connect the test leads in parallel with 
the circuit being measured. 
4. Read the measured voltage on the 
instrument display.   
 
 
5.3 AC/DC 
Current 
Measurements 
 
WARNING 
To avoid injury, do not attempt a current measurement if the open circuit voltage 
exceeds the rated voltage of the meter. 
 
 
1.  If the current to be measured is unknown, connect the red test 
lead to the 
‘A’
 jack. If it is known or has been determined that 
the current is 400mA or less, connect the red lead to the 
‘µA/mA’ 
jack. Connect the black test lead to the 
‘COM’
 jack.   
2. Set the Function Selector switch to the current range 
corresponding to the jack being used and press the blue 
button to select AC or DC. 
3.  Remove power from the circuit to be measured and connect 
the instrument in series with this circuit. Connect the black 
lead to the negative (-) side and the red lead on the positive (+) 
side being measured. 
4.  Apply power to the circuit and read the measured current on 
the instrument display. 
 
 
MODEL 110 AUTORANGING DIGITAL MULTIMETER 
 
 
 
 
 
 
 
 
 
 
 
 
 
uA or mA measurement 
Amp measurement 
 
5.4 Resistance 
Measurements 
 
WARNING 
Before making any in-circuit measurements, remove power from the circuit being 
tested and discharge all capacitors in the circuit. 
 
1.  Connect the red test lead the to 
:
 jack 
and the black test lead to the 
‘COM’
 jack. 
2. Set  the  Function  Selector switch to   
the     range and press the blue 
button to select the 
: function. 
3. Remove power from the circuit being 
tested and discharge all capacitors in 
the circuit. 
4.  Connect the test leads in parallel with 
the circuit to be measured and read the 
measured resistance on the instrument 
display.