Справочник Пользователя для Mocomtech CDM-570

Скачать
Страница из 452
CDM-570/570L Satellite Modem with Optional IP Module 
Revision 4 
Appendix F 
MN/CDM570L.IOM 
F.3.3.30 (ODU,ENABLE,1:1,CSAT#1,CONFIG, MISCELLANEOUS,LNA) 
  FAULT-LOGIC 
  (ODU,ENABLE,1:1,CSAT#2,CONFIG, 
MISCELLANEOUS,LNA) 
  FAULT-LOGIC 
  (ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS,LNA) 
  FAULT-LOGIC 
 LNA Fault Logic: Summary 
 No-Summary     (
◄ ►,
ENT) 
 
The user is prompted to select either Summary or No Summary, using the ◄ ► arrow 
keys, then to press ENT.  This controls whether or not a LNA Current-Window fault will 
activate the SUMMARY FAULT RELAY.  This allows the user to select whether or not 
to switch the ONLINE/OFFLINE CSAT in the event of a LNA current-window fault. 
F.3.3.31 (ODU,ENABLE,1:1,CSAT#1,CONFIG,MISCELLANEOUS) 
   
 
 
EXT-REF 
  (ODU,ENABLE,1:1,CSAT#2,CONFIG,MISCELLANEOUS) 
   
 
 
EXT-REF 
  (ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS) 
 
 
EXT-REF 
 ExternalRef Fault Logic:     
 Summary No-Summary  (
◄ ►
) 
The user is prompted to select either Summary or No-Summary, using the ◄ ► arrow 
keys, then to press ENT.  NOTE: The CSAT will automatically lock to an external 5 or 
10 MHz reference independent of the state of this selection.  This selection determines 
whether or not the Summary Fault Relay is activated if the CSAT loses lock with the 
external reference. 
F.3.3.32 (ODU,ENABLE,1:1,CSAT#1,CONFIG,MISCELLANEOUS) 
    
 
 
REF-ADJUST 
  (ODU,ENABLE,1:1,CSAT#2,CONFIG,MISCELLANEOUS) 
   
 
 
REF-ADJUST 
  (ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS) 
 
 
REF-ADJUST 
 Internal Ref Adjustment:  
 087            (
▲ ▼,ENT) 
 
The user is prompted to edit the Internal 10MHz Reference setting using the ▲ ▼ arrow 
keys, then to press ENT.  The value will scroll between 000 and 255.  NOTE: The 
Internal Reference is adjusted in the factory to be very accurate with the default setting of 
087.  This parameter is made available to compensate for the long-term frequency drift of 
the oscillator. 
F–12