3.4.2 Batch monitoring of device values
3 - 35
1
OV
E
R
VI
EW
2
CRE
A
T
E
D
 PROGRAM 
AN
D SYS
TEM 
CONF
IGURA
TION
3
CR
EA
TI
NG PR
O
G
R
A
M
 IN
 
S
TRUC
TUR
E
D
 L
A
DDE
R/
FB
D
 LA
NG
UA
G
E
4
CREA
T
ING 
PROG
RAM IN ST 
LANGUAGE
5
CRE
A
TI
NG T
W
O OR 
MORE PROGRAM 
BLO
C
K
S
3.4 Monitoring Operations
4.
Set the Display Format of the device to be 
monitored.
Setting on the Display Format screen
• Monitor Format
: Bit and Word
• Display
: 16 bit Integer
• Value
:  DEC
• Bit Order
: 0-F
• Switch No. of Points : Bit Device Bit and Word 
Format 16 Points
After the setting, click the 
 button to close 
the Display Format screen.
Refer to the following manual for the details on 
Display Format.
GX Works2 Version 1 Operating Manual 
(Common)
5.
Click 
 (Start Monitoring) on the toolbar to 
start monitoring.
6.
Set the programmable controller CPU to RUN.
Set the RUN/STOP switch on the programmable 
controller CPU to "RUN".
7.
Click 
 (Stop Monitoring) on the toolbar to 
stop monitoring.
Monitored values remain even after GX Works2 
stops monitoring.
● You can save the contents set on the Display Format screen.
When the monitoring screen is opened again, the contents set previously on the Display Format  
screen will not be displayed. (The default setting will be displayed.) To display the previous 
setting, you can save the setting to a file, and read the file. To save the setting, click Save 
Display Format on the Device/Buffer Memory Batch Monitor screen. To read the saved setting, 
click Open Display Format on the Device/Buffer Memory Batch screen Monitor screen.