Справочник Пользователя для Mitsubishi Electronics J2-JRSERIES MR-J2-03A5

Скачать
Страница из 185
6 -  7
6. DISPLAY AND OPERATION
(b)  5-digit parameter
The following example shows the operation procedure performed to change the electronic gear
denominator (parameter No. 4) into "12345":
Call the display screen shown after power-on.
Press MODE once. Select parameter No. 4 with UP / DOWN.
Press SET once.
Press MODE once.
Fifth digit setting
Press SET once.
The screen flickers.
⋅⋅⋅⋅⋅⋅
⋅⋅⋅⋅⋅⋅
Change the set value
with UP / DOWN.
Press SET once.
The set value is enterd.
⋅⋅⋅
⋅⋅⋅
Press UP or DOWN.
To the next parameter
Lower 4 digits setting
Press SET once.
(2) Expansion parameters
To use the expansion parameters, change the setting of parameter No. 19 (parameter write disable).
Refer to section 5.1.1.