Справочник Пользователя для Marquis DVT-38

Скачать
Страница из 31
Marquis 38 
5 
GENERAL INFORMATION 
This appliance is listed by Warnock Hersey for use in both the United States and Canada. It is tested and 
certified to the following US and Canadian gas appliance standards. 
 
- ANSI Z21.50-1996 / CGA 2.22-M96, Vented Gas Fireplace and Heaters 
- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes. 
Please contact Archgard Industries Ltd. if you have any questions regarding the certification of this 
appliance. 
APPLIANCE CERTIFICATION 
INSTALLATION CODES 
This appliance must be installed by a qualified gas appliance installer. 
The installation must conform with the local codes or, in the absence of local codes, with the 
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,  
CAN/CGA-B149, in Canada. 
Electrical  connections and grounding must conform with local code, or current National 
Electrical code, ANSI/NFPA No. 70-1987, in the US and in Canada, the current Canadian 
Electrical Code, CSA C22.1. 
HIGH ALTITUDE INSTALLATION  
When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be 
properly de-rated and installed according to local codes. In the absence of local codes, with the 
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,  
CAN/CGA-B149, in Canada. 
 
Natural Gas (NG) 
Propane (LP) 
Manifold Pressure 
 3.5 in. w.c. ( 0.9 kPa) 
10.0 in. w.c. ( 2.5 kPa) 
Min. Supply Pressure for 
Purpose of Input Adjustment  
4.5 in. w.c. (1.2 kPa) 
11.0 in. w.c. (2.8 kPa) 
Orifice Size 
#48 DMS ( 1.93 mm dia.) 
#56 DMS ( 1.18 mm dia.) 
Nominal Input Rating 
16,000 BTU/hr (4.6 kW)  
16,000 BTU/hr ( 4.6 kW) 
Altitude 
0 - 4,500 ft. (0 - 1372 m) 
0 - 4,500 ft. (0 - 1372 m) 
Primary Air Opening 
¼ in. (6 mm) 
½ in. (13 mm) 