WARNING:  BE ABSOLUTELY SURE THE DISTANCE BETWEEN 
THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE 
CONSTRUCTION IS NOT LESS THAN SHOWN.
Floor Protection  
USA - The floor in front and under the heater must be pro-
tected with a minimum of 3/8” thick noncombustible material. 
The covering must extend 16” in front of the door opening 
of the heater and 8” to either side of the door opening and 
5-1/2” to the rear or to the wall, whichever is smaller. In all 
installations a 16” minimum hearth extension (in front of 
the stove) is required as measured from the door opening 
of the unit.
Canada - The floor in front and under the heater must be 
protected with a minimum of 3/8” thick noncombustible 
material. The covering must extend 457 mm in front of the 
door opening of the heater and 200mm to either side of the 
stove body and 200 mm to the rear or to the wall, whichever 
is smaller. In all installations a 457mm minimum hearth 
extension (in front of the stove) is required as measured 
from the door opening of the unit.
Reduced Clearances
Clearances to combustible surfaces can be reduced with the 
use of listed double wall connector pipe. See the clearances 
with double wall pipe on the following page.
Alcove Clearances
Single Wall Pipe - Minimum 48"(1219mm) width, maxi-
mum 48" (1219mm) depth. Minimum ceiling height is 72” 
(1829m).
Double Wall Pipe - Minimum 44"(1117mm) width, maxi-
mum 48" (1219mm) depth. Minimum ceiling height is 72” 
(1829m).
Mobile Home Installations
All mobile home installations require an outside air kit (part # 
71111 or 71112). The stove must be bolted to the floor and 
grounded to the chassis of the mobile home.
WARNING:  DO NOT INSTALL IN SLEEPING ROOM OF A 
MOBILE HOME.
CAUTION:  THE STRUCTURAL INTEGRITY OF THE MOBILE 
HOME  FLOOR,  WALL,  AND  CEILING/ROOF  MUST  BE 
MAINTAINED.
Approved Chimney* - Your stove is approved for use with 
Class A, UL 103HT Chimney and double wall connector pipe 
from Security™ Chimneys.
Clearances to connector pipe shall be measured from the 
flue collar of the stove. 
 
Chimney & Connector
Minimum 6" diameter, minimum 24 MSG black steel con-
nector pipe with listed factory-built chimney suitable for use 
with solid fuels or masonry chimney. Horizontal connection 
not tested, refer to local building codes for installation. Re-
strictions apply! Read instructions before installing.
Clearance dimensions are to 6” (152mm) flue collar. If a 
single wall connector pipe with shield is used, a 1 inch air 
space is needed between pipe and shield. Shield attaches 
to rear of stove pipe and must run from stove top to ceiling. 
Pipe shield shall be UL listed. 
Residential chimney systems must be from the same brands 
as listed for mobile homes but connector pipe may be double 
wall, single wall or single wall with shield as listed above.
Connector pipe and chimney must be of the same brand.
Components Required For Installation
Legs AND Bottom Heat Shield or Pedestal Base.
If optional blower is NOT used, Rear Heat Shield Block Off 
Plate shall be installed.
* Other approved chimney brands are Projet, Jakes Evans/GSW, Dura-vent, 
Metal Fab, Ameri-Tec, Metalbestos and Industrial Chimney (ICC).