Appendix A – NMEA 2000 Interfacing 
Page A1 
 
®
®
Appendix A – NMEA 2000
®
 Interfacing 
 
RIM100 NMEA 2000
®
 Periodic Data Transmitted PGNs 
 
PGN 127501 – Binary Switch Bank Status 
The RIM100 uses this PGN to transmit the state of each of the connected switch inputs 
 
Field  1:  Indicator Bank Instance – This field identifies the particular switch bank to which this 
PGN applies. Please refer to Section 2.5.1 for instructions on how to program the 
value of this field. 
 
2:  Indicator #1 – This field indicates the state of the switch connected to the V1+ and 
V1- inputs of the RIM100. The state will be one of the following values: 
•  “Off” – No voltage is detected on the monitored load (the load is not running). 
•  “On” – A voltage is detected on the monitored load (the load is running). 
•  “Data Not Available” – The indicator is configured as “Disabled” 
 
3:  Indicator #2 – This field indicates the state of the switch connected to the V2+ and 
V2- inputs of the RIM100. 
 
4:  Indicator #3 – This field indicates the state of the switch connected to the V3+ and 
V3- inputs of the RIM100. 
 
5:  Indicator #4 – This field indicates the state of the switch connected to the V4+ and 
V4- inputs of the RIM100. 
 
6:  Indicator #5 – This field indicates the state of the switch connected to the V5+ and 
V5- inputs of the RIM100. 
 
7:  Indicator #6 – This field indicates the state of the switch connected to the V6+ and 
V6- inputs of the RIM100.