Event / Sensor 
ALARM INPUT
Configurations for any external alarm device 
(i.e. a Door or Window Sensor). Refer to 
page 73 for hardware configuration details.
•  Operation  - Sets the Alarm Sensor 
Connection Status (Enable / Disable) for 
an external alarm (i.e. Door or Window 
Sensors). Refer to page 73 for setup 
diagram.
• Type: Sets the Alarm Sensor type to N/
O (Normally Open) or N/C (Normally 
Closed).
z
N/O (Normally Open) - Select for an 
Alarm that has a Normally Open circuit (such 
as a door that remains open). An Alarm will 
occur when this is changed to a Closed 
status.
z
N/C (Normally Closed) - Select for an 
Alarm that has a Normally Closed circuit 
(such as a Window Sensor). An Alarm will 
occur when this is changed to a Opened 
status.
ALARM OUT
Sends an Alarm Out signal to a device (such 
as a Manual Door or independent Light/
Buzzer Alarm) when an Alarm In event is 
detected
• Channel - Select a Channel to configure.
• Mode - Setup Reacted Relay as either 
Latched or Transparent Mode:
z
Latched – When sensor alarm activated, 
relay reacted in setup duration. 
z
Transparent – Relay reacted temporary 
during sensor alarm activate.
• Type - Set the Relay Type to either N/O 
(Normally Open) or N/C (Normally 
Closed).
• Operation - Setup Relay Connect with 
Alarm Sensor to either Enable or 
Disable.