Справочник Пользователя для Lucent Technologies Definity Enterprise Communication Server 8.2
DEFINITY ECS Release 8.2
Administrator’s Guide
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
949
System Parameters OCM Call Classification
17
Global Classifier Adjustment (dB)
Enter a number to specify the dB loss adjustment.
USA Default Algorithm
USA SIT Algorithm
Field descriptions for page 2
Screen 199.
System Parameters OCM Call Classification screen
Valid entries
Usage
0
to
15
0
is the least and
15
the most adjustment.
Valid entries
Usage
y/n
To use the default United States tone detection, set this field to
y
. If you enter
n
, the US Special Information Tones (SIT)
Algorithm field appears.
Valid entries
Usage
y
To use the United States (SIT) tone characteristics for SIT tone
detection.
detection.
n
The system treats tones with the administered tone name
“intercept” as if they were SIT VACANT, and treats tones with
the administered tone name “information” as if they were SIT
UNKNOWN.
“intercept” as if they were SIT VACANT, and treats tones with
the administered tone name “information” as if they were SIT
UNKNOWN.
Page 2 of 9
SYSTEM PARAMETERS OCM CALL CLASSIFICATION
Tone Name
Instance
Tone
Cadence
Duration
Duration
Continuous
Step
Minimum
Maximum
_________
_____
___
1.
on
_____
_____
2.
off
_____
_____
3.
on
_____
_____
4.
off
_____
_____
5.
on
_____
_____
6.
off
_____
_____
7.
on
_____
_____
8.
off
_____
_____