25 
coMMANd 1: PReSet dUMP
This sysex is transmitted by a MIDI sequencer or by PCM92. The PCM92 
may transmit this dump in response to a request or by means of a front-pan-
el action. The PCM92 receiving this dump will store the encapsulated preset 
data in the designated location.
Byte
Definition
Comments
0xF0 
Sysex message 
 
0x06 
Lexicon Manufacturer ID
0x__ 
Product ID 
 
0x__ 
Device ID 
0x01 
Command 
Preset Dump
0x__ 
Size 
LSB. Size is variable and is not shown in this 
example
0x__ 
Size 
cont
0x__ 
Size 
cont
0x__ 
Size 
MSB
0x__ 
Bank 
Bank in which the preset is to be placed.
0x__ 
Preset 
Location in the bank where the preset is to 
be placed.
... 
Preset data 
Nibbleized preset data.
0xF7 
EOX 
   
coMMANd 2: ReQUeSt PReSet bANK dUMP
When this command is received by the PCM92, it will respond with a series 
of preset dumps for all presets in the bank. Blank presets will be transmitted 
in a special form. Only presets from User banks may be requested. Factory 
banks will not be transmitted.
Byte
Definition
Comments
0xF0 
Sysex message 
 
0x06 
Lexicon
®
 Manufacturer ID
0x__ 
Product ID 
 
0x__ 
Device ID 
 
0x02 
Command 
Request Preset Bank Dump
0x01 
Size 
LSB
0x00 
Size 
cont
0x00 
Size 
cont
0x00 
Size 
MSB
0x__ 
Bank 
Bank to fetch
0xF7 
EOX