Справочник Пользователя для Lexmark C760

Скачать
Страница из 402
PJL
3-17
 
PARALLEL
(DEFAULT only)
(Port Specific)
Parallel Protocol
SLOW, FAST
A value of SLOW indicates the Parallel Protocol 
setting is Standard. The value of FAST indicates the 
Parallel Protocol setting is FASTBYTES.
INQUIRE or DINQUIRE returns the value of the 
Parallel Protocol as follows:
• If Parallel Protocol is set as Standard, SLOW is 
returned.
• If Parallel Protocol is set as Fastbytes, FAST is 
returned.
FAST
PASSWORD
(DEFAULT only)
Default password 
for PJL NVRAM 
security
0 to 65535
Locks the printer operator panel to keep the user 
defaults from changing. See your printer 
documentation for more information.
The Default PJL password is 0.
If the PJL password is not equal to 0, a DINQUIRE or 
INQUIRE on the PASSWORD variable returns 
ENABLED. If the PJL password is equal to 0, a 
DINQUIRE or INQUIRE on the PASSWORD variable 
returns DISABLED. See the PASSWORD parameter 
of the JOB command on page 3-5 for more 
information.
0
PERSONALITY
(Port specific)
SmartSwitch 
settings
PCL, POSTSCRIPT, AUTO
PERSONALITY controls the SmartSwitch settings for 
the interface link on which the PJL command is 
received.
If AUTO is sent, both 
PS SmartSwitch
 and 
PCL 
Smartswitch
 menu settings are set to ON.
If PCL is sent, 
PS SmartSwitch
 is set to OFF and 
PCL 
SmartSwitch
 is set to ON.
If POSTSCRIPT is sent, 
PCL SmartSwitch
 is set to 
OFF and 
PS SmartSwitch
 is set to ON.
When queried, AUTO is returned if both SmartSwitch 
settings are ON. If one SmartSwitch setting is OFF, 
the printer language whose SmartSwitch setting is ON 
is returned. If both SmartSwitch settings are OFF, the 
default printer language is returned.
AUTO
POWERSAVE
(DEFAULT only)
Power Save 
feature
ON, OFF
ON enables the power-saving feature.
OFF disables the power-saving feature.
Note: 
Some printer models released in the year 2000 
or later designated as Energy Star printers cannot 
have Power Saver disabled.
ON
Table 3-3:  Common Variables for Both Printer Languages (Continued)
Variable
Function
Selections
Factory Default