10. MAIN ANALOG INSTRUMENT PANEL
Installation of the IVECO MOTORS onboard panel with
analog indicators entails connecting the panel’s JC connec-
tor to the JB connector on engine wire harness, interposing
the appropriate extension wire harness available in 3, 5 and
7 meter-long versions. The JC-JB wire harness comprises 47
lines, each connected to the terminal identified on both con-
nectors by the same number.
To the main panel is connected the JE connector, provided
for connection to the secondary panel; in installations with
no secondary panel, do not remove the cap of the JE con-
nector to avoid compromising the electrical continuity of the
systems’ power supply circuit.
To allow the work of the fuel filter clogging alarm (SIFC), in
the indication alarm module, it has to disconnect the connec-
tor (12) fitted close to JC.
Figure 2
1. Coolant temperature gauge (TA) - 2. Revolution counter and hour counter (CG) - 3.Voltmeter (V) - 4. Buzzer (SA) - 5. Indication
and alarm module (MS) - 6. Engine oil pressure gauge (MO) - 7. Connector for secondary instrument panel (JE)- 8. On board panel
instrument light switch (L) - 9. Engine start/stop key switch (CA) -10. Engine stop push-button (usable only with electric harness
versions with excitation engine stop) - 11. Sound alarm inhibition push-button (P1) -12. SIFC Alarm abilitation connector -
13. Connector for main panel wiring (JC) - 14. Cap with electrical continuity connection.
oF
oC
V
bar
06_002_S
1
13
2
3
4
5
6
7
11
10
9
8
14
12