Conformance
The IRIS range of alarm dialers comply with the following European Directives:
• 
1999/5/EC (Radio & Telecoms Terminal Equipment Directive).
• 
72/23/EEC (Low Voltage Directive).
• 
89/336/EEC (Electromagnetic Compatibility Directive as amended by
92/31/EEC).
Conformance to EN50131 and EN50136
The IRIS dialers are compatible with the requirements of European standards
prEN50131-1 (Alarm Systems – Intrusion and hold-up systems Part 1: System
Requirements) (dated Feb 2004) and EN50136-1-1 (Alarm Systems – Alarm
transmission systems and equipment) (January 1998 with Amendment 1 August
2001) as follows:
• 
The IRIS dialers conform to Environmental Class II.
• 
The IRIS dialers are compliant to ATS 6 compatible with Security
Grade 4.
Safety
Care should be taken when interconnecting telecommunications equipment that
only like interfaces are interconnected to avoid safety hazards.
SELV:
SELV (Safety Extra-Low Voltage) is defined as a secondary circuit
which is so designed and protected that under normal and single fault
conditions the voltage between any two accessible parts does not
exceed a safe value (42.4V peak or 60V dc maximum).
The interfaces on the IRIS dialer have the following safety classifications:
• 
Dialer Interface: SELV suitable for connection to the TNV interface of a
single line telecommunications equipment such as telephones, faxes,
etc.
• 
Data Interface: SELV suitable for connection to the SELV interface on a
data terminal such as a PC COM port.
• 
Power Interface: SELV for connection to a DC supply.
• 
Inputs and Outputs: SELV for connection to alarm output and input
pins.