Справочник Пользователя для Intex Recreation CS8110

Скачать
Страница из 30
131
SAVE THESE INSTRUCTIONS
Page 19
(131)  MODEL CS8110  SALTWATER SYSTEM ENGLISH  7.5” X 10.3”  PANTONE 295U  
07/28/2010
English
OO
PP
EE
RR
AA
TT
IINN
GG
  II
NN
SS
TT
RR
UU
CC
TT
IIOO
NN
SS
8.
Boost cycle
If the test result is below 0.1ppm, press and hold “BOOST” 
button for 5 seconds until the indicator lights up and the 
LED display “80”. This indicates that the saltwater 
system has started copper ion production.
You can press and hold the “BOOST” button for another 5 
seconds until the indicator is off, which will cancel the Boost 
cycle. 
Note: Once the system has started copper ion production, the 
boost button can’t be re-set until the power switch is off. 
The boost operating hours is 4 times the amount of time programmed into the 
system, i.e. if your saltwater system operating time is 2 hours, the boost procedure 
will run 4 x 2 = 8 hours. After boost procedure has been completed, the system 
will automatically switch to the normal working mode.
Once the boost is operating, check whether the filter pump operating hours 
have been set properly. For example, the boost operating time is 8 hours, the 
filter pump should be set to run for 8 hours at least. Increase the filter pump 
operating time if necessary. 
Note: If an Intex filter pump is attached to the system, set the pump switch to 
on “I” position.
After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the 
pool again.
9.
Test pool water regularly:
Once the copper level appears to be balanced, test the pool water every week 
to maintain the proper sanitizer level.
It’s very important that the free chlorine is between 0.4-1.5 ppm and copper 
ion concentration is between 0.1~0.2 ppm. When the copper level is below 0.1 
ppm, repeat step 8.
NOTE: A High copper ion concentration may cause blonde hair to exhibit a 
green hair. To prevent this, wear a swimming cap during swimming, and wash 
hair with special shampoo after using the pool. 
See “Troubleshooting Guide”.
10. Stand-by/power saving mode:
When the cycle ends, the green “SLEEP” indicator on the 
control panel lights up and the LED display flashes “93”. 
The system is now in Stand-By mode. After a while, it 
shuts down and sets itself in a Power Saving mode. The 
system will automatically turn itself back on in 24 hours, 
starting its daily cycle of chlorine production.
The “SLEEP” indicator stays on, while the system is in the 
Power Saving mode. The LED display however, goes blank 
after 1 hour. Press any button (      or      ) to view the last LED 
code.
OPERATION INSTRUCTIONS (continued)