Справочник Пользователя для Intex Recreation CS8110

Скачать
Страница из 30
131
SAVE THESE INSTRUCTIONS
Page 22
(131)  MODEL CS8110  SALTWATER SYSTEM ENGLISH  7.5” X 10.3”  PANTONE 295U  
07/28/2010
English
MM
AA
IINN
TT
EE
NN
AA
NN
CC
EE
MAINTENANCE (continued)
3.  Disconnect the 2 hoses from the Saltwater System,  and assemble the cell 
cover (10) at each side of the cell.
4.
In a counter-clockwise motion, unscrew the collar of the copper electrode (5) 
and remove it from the electrolytic cell (4). Lift up the copper electrode.
5.
Pour kitchen grade vinegar into the cell to immerse the titanium plates. Then 
put the copper electrode back in the cell, soak them for about one hour until 
no colored areas remain. 
6.  Open one side of the cell cover (10), drain and properly dispose of the vinegar. 
Connect the hose which goes from the pool to the cell. Flush the cell with the 
pool water.
7.  Reverse steps 3, 4, 5 and 6 to reconnect the electrolytic cell.