Справочник Пользователя для International Home Products Centiva Floors

Скачать
Страница из 21
ULTRASTONE  Rialto 
 
Construction:   
Solid Vinyl Tile 
Standard Sizes:   
12” x12”, 18” x 18”, and 36” x 36” slabs; custom sizes  
Gauge:   
.120 mil (3mm) 
Wearlayer:   
Clear Rigid, High-Density PVC of .30 Mil 
Packaged:   
45 s/f per carton (12” x 12”, 18” x 18”); 90 s/f per carton of 36” x 36” 
   
For larger projects, slabs of 36” x 36” may be put on pallets rather than in cartons with a 
maximum of 240 slabs = 2,160 s/f 
Approximate Weight:   
47 lbs per 12” x 12” or 18” x 18” carton;   94 lbs per 36” x 36” carton 
Surfaces:   Frost 
Edge Treatments:   
Square or slight bevel 
Standard Colors:   
4 plus custom colors*  
Slip Resistance:   
D-2047-82 Static Coefficient of Friction on wet and dry surfaces 
Critical Radiant Flux:   
ASTM E-648 .45 Watts/cm
2
 or less; NFPA 101 Life Safety Code Class I Passes 
Recommended Static Load:   
285 lbs. per square inch 
Smoke Generation:   
ASTM E-662  450 or less in flaming mode, Passes 
Flame Spread:   
75 or less (ASTM E-84) Class B Passes 
 
 
 
 
 
PLANKWOOD 
 
Construction:   
Solid Vinyl Tile 
Standard Sizes:   
6” x 36” and custom 
Gauge:   
.120 mil (3mm) 
Wearlayer:   
Clear Rigid, High-Density PVC of .30 Mil 
Packaged:   
36 s/f per carton  
Approximate Weight:   
30 lbs per carton 
Surfaces:   Tick 
Edge Treatments:   
Square  
Standard Colors:   
11 plus custom colors* 
Slip Resistance   
D-2047-82 Static Coefficient of Friction on wet and dry surfaces 
Critical Radiant Flux;   
ASTM E-648 .45 Watts/cm
2
 or less; NFPA 101 Life Safety Code Class I Passes 
Recommended Static Load:   
285 lbs. per square inch 
Smoke Generation:   
ASTM E-662  450 or less in flaming mode, Passes 
Flame Spread:   
75 or less (ASTM E-84) Class B Passes 
 
 
 
ULTRAPLANK 
 
 
Construction:   
Solid Vinyl Tile 
Standard Sizes:   
4” x 36” and custom 
Gauge:   
.120 mil (3mm) 
Wearlayer:   
Clear Rigid, High-Density PVC of .30 Mil 
Packaged:   
45 s/f per carton  
Approximate Weight:   
47 lbs per carton 
Surfaces:   Tick 
Edge Treatments:   
Slight Bevel  
Standard Colors:   
16 plus custom colors* 
Slip Resistance   
D-2047-82 Static Coefficient of Friction on wet and dry surfaces 
Critical Radiant Flux:   
ASTM E-648 .45 Watts/cm
2
 or less; NFPA 101 Life Safety Code Class I Passes 
Recommended Static Load:   
285 lbs. per square inch 
Smoke Generation:   
ASTM E-662  450 or less in flaming mode, Passes 
Flame Spread:   
75 or less (ASTM E-84) Class B Passes