Page 35
INF7020 Hardware Guide
NOTES:
•  When executing ALL RESET, set the timeout period to 30 seconds or longer.
•  When turning the power on while the POWER ON DELAY function is in use, set the timeout period to the POWER ON DELAY 
period + 10 seconds or longer. 
Gamma User Data
TO TRANSFER THE GAMMA USER DATA
Use the user data transfer commands (UGRW, UGGW andUGBW). For each of the R, G and B colors, divide the total 512 pieces of 
user data into 16 blocks, and transfer 32 pieces of data with each command.
C1 C2 C3 C4 P1 P2 P3 P4
… S1 S2
  
 
UGRW01000000010002 … 0031C0
•  If data is less than 4 digits, add a “0” (zero) to make it 4 digits.
•  The checksum field is the character string (ASCII) data of lower-order one byte which indicates the sum of the block number and 
32 pieces of data in hexadecimal (0 to F).
SAVING THE GAMMA USER DATA
Use the user data save command (UGSV) to save the transferred user data in the monitor.
If the data is not saved, it will be cleared when:
•  The monitor power switch is off.
•  STANDBY MODE is LOW POWER and the monitor enters standby mode.
ACTIVATING THE GAMMA USER DATA
To activate the transferred user data, select USER for GAMMA of the PICTURE menu, or send the corresponding RS-232C
command.
CHECKING THE GAMMA USER DATA
Use the user data read commands (UGRR, UGGR and UGBR) to return 512 pieces of user data for each of the R, G and B colors. Di-
vide the data into 16 blocks and return 32 pieces of data with each command. The value to be returned is not the value stored in the 
monitor, but the value in the temporary memory for display. (These values are the same when the user data save command (UGSV) 
above has been sent.)
NOTES:
• The user data is not initialized by RESET of the PICTURE menu. To initialize the user data, use ALL RESET of the FUNCTION menu. 
The GAMMA user data initialize command (UGRS) allows the initialization of the user data only.
Command   Block Number
32 pieces of data
Checksum
One piece of data consists
of 4 digits.
Example: To transfer the data of block 1 (0 to 31 levels) 
of red (R) data
Command field   Block Number (01 to 16)  Data field     Checksum field