Attention:
  
To
 
avoid
 
damage
 
to
 
the
 
hardware,
 
take
 
special
 
care
 
when
 
you
 
restart
 
the
 
system
 
after
 
an
 
unexpected
 
shutdown.
 
If
 
the
 
storage
 
server
 
shuts
 
down
 
unexpectedly,
 
go
 
to
 
Otherwise,
 
go
 
to
 
Note:
  
Unattended
 
restoration
 
of
 
power
 
is
 
supported;
 
however,
 
if
 
power
 
restoration
 
is
 
attended,
 
you
 
should
 
follow
 
the
 
best
 
practices
 
guidelines
 
and
 
the
 
power
 
restoration
 
sequence
 
in
 
 
Performing
 
an
 
emergency
 
shutdown
 
 
Attention:
  
Emergency
 
situations
 
might
 
include
 
fire,
 
flood,
 
extreme
 
weather
 
conditions,
 
or
 
other
 
hazardous
 
circumstances.
 
If
 
a
 
power
 
outage
 
or
 
emergency
 
situation
 
occurs,
 
always
 
turn
 
off
 
all
 
power
 
switches
 
on
 
all
 
computing
 
equipment.
 
This
 
will
 
help
 
safeguard
 
your
 
equipment
 
from
 
potential
 
damage
 
due
 
to
 
electrical
 
surges
 
when
 
power
 
is
 
restored.
 
If
 
the
 
storage
 
server
 
loses
 
power
 
unexpectedly,
 
it
 
might
 
be
 
due
 
to
 
a
 
hardware
 
failure
 
in
 
the
 
power
 
system
 
or
 
midplane
 
(see
 
 
Use
 
this
 
procedure
 
to
 
shut
 
down
 
the
 
storage
 
server
 
during
 
an
 
emergency:
 
1.
   
If
 
you
 
have
 
time,
 
stop
 
all
 
I/O
 
activity
 
to
 
the
 
storage
 
server
 
by
 
shutting
 
down
 
the
 
host
 
or
 
disconnecting
 
the
 
storage
 
server
 
logical
 
drives
 
through
 
the
 
host.
 
2.
   
Check
 
the
 
LEDs
 
(front
 
and
 
back).
 
Make
 
note
 
of
 
any
 
Fault
 
LEDs
 
that
 
are
 
on
 
so
 
you
 
can
 
correct
 
the
 
problem
 
when
 
you
 
turn
 
on
 
the
 
power
 
again.
 
3.
   
Turn
 
off
 
all
 
power-supply
 
switches;
 
then
 
unplug
 
the
 
power
 
cords
 
from
 
the
 
storage
 
server.
Restoring
 
power
 
after
 
an
 
emergency
 
shutdown
 
Use
 
this
 
procedure
 
to
 
restart
 
the
 
storage
 
server
 
if
 
you
 
turned
 
off
 
the
 
power-supply
 
switches
 
during
 
an
 
emergency
 
shutdown,
 
or
 
if
 
a
 
power
 
failure
 
or
 
a
 
power
 
outage
 
occurred:
 
1.
   
After
 
the
 
emergency
 
situation
 
is
 
over
 
or
 
power
 
is
 
restored,
 
check
 
the
 
storage
 
server
 
for
 
damage.
 
If
 
there
 
is
 
no
 
visible
 
damage,
 
continue
 
with
 
step
 
2;
 
otherwise,
 
have
 
your
 
system
 
serviced.
 
2.
   
After
 
you
 
have
 
checked
 
for
 
damage,
 
ensure
 
that
 
the
 
power-supply
 
switches
 
are
 
off;
 
then
 
plug
 
in
 
the
 
storage-server
 
power
 
cords.
 
3.
   
Complete
 
step
 
to
 
determine
 
the
 
proper
 
power-on
 
sequence
 
for
 
your
 
system.
 
4.
   
Complete
 
steps
 
and
 
to
 
turn
 
on
 
power
 
to
 
the
 
devices
 
in
 
your
 
system
 
and
 
to
 
check
 
the
 
status
 
of
 
the
 
storage
 
server.
Restoring
 
power
 
after
 
an
 
over-temperature
 
shutdown
 
Use
 
this
 
procedure
 
to
 
restart
 
the
 
storage
 
server
 
after
 
an
 
unexpected
 
shutdown
 
due
 
to
 
an
 
over-temperature
 
condition:
 
1.
   
Make
 
sure
 
that
 
the
 
power-supply
 
switches
 
on
 
the
 
back
 
of
 
the
 
storage
 
server
 
are
 
turned
 
off.
 
2.
   
Do
 
whatever
 
is
 
necessary
 
to
 
cool
 
the
 
unit
 
(replace
 
the
 
fans,
 
use
 
external
 
fans
 
to
 
cool
 
the
 
room,
 
and
 
so
 
on).
 
3.
   
Check
 
all
 
components
 
and
 
cables
 
for
 
visible
 
damage.
 
Do
 
not
 
start
 
the
 
storage
 
server
 
if
 
you
 
find
 
evidence
 
of
 
damage.
 
 
 
Chapter
 
4.
 
Operating
 
the
 
storage
 
server
 
69