Both
 
fan
 
units
 
must
 
always
 
be
 
in
 
place,
 
even
 
if
 
one
 
is
 
not
 
functioning
 
properly,
 
to
 
maintain
 
proper
 
cooling.
 
Use
 
the
 
following
 
procedure
 
to
 
replace
 
a
 
hot-swap
 
fan:
 
1.
   
Check
 
the
 
LEDs
 
on
 
the
 
back
 
of
 
the
 
storage
 
server.
 
2.
   
If
 
the
 
amber
 
Fault
 
LED
 
is
 
on,
 
remove
 
the
 
fan
 
CRU
 
that
 
has
 
failed.
 
a.
   
Slide
 
the
 
latch
 
to
 
unlock
 
the
 
fan
 
CRU.
 
b.
   
Use
 
the
 
handle
 
(black
 
knob)
 
to
 
pull
 
the
 
fan
 
from
 
the
 
storage
 
server.
 
See
 
 
3.
   
Install
 
the
 
new
 
fan
 
unit.
 
a.
   
Place
 
the
 
fan
 
CRU
 
in
 
front
 
of
 
the
 
fan
 
slot.
 
b.
   
Hold
 
the
 
latch
 
open,
 
and
 
slide
 
the
 
fan
 
all
 
the
 
way
 
into
 
the
 
slot.
 
If
 
the
 
fan
 
does
 
not
 
go
 
into
 
the
 
bay,
 
rotate
 
it
 
180°.
 
Ensure
 
that
 
the
 
latch
 
is
 
on
 
the
 
side
 
closest
 
to
 
the
 
center
 
of
 
the
 
storage
 
server.
 
c.
   
Release
 
the
 
latch.
 
If
 
the
 
lever
 
remains
 
open,
 
pull
 
back
 
on
 
the
 
fan
 
slightly,
 
and
 
then
 
push
 
it
 
in
 
again
 
until
 
the
 
latch
 
snaps
 
into
 
place.
4.
   
Check
 
the
 
LEDs.
 
The
 
Fault
 
LEDs
 
turn
 
off
 
after
 
a
 
few
 
seconds.
 
If
 
they
 
remain
 
on,
 
see
 
Working
 
with
 
power
 
supplies
 
The
 
power
 
supply
 
CRUs
 
provide
 
power
 
to
 
the
 
internal
 
components
 
by
 
converting
 
incoming
 
ac
 
voltage
 
to
 
dc
 
voltage.
 
The
 
DS4100
 
base
 
storage
 
server
 
power
 
system
 
operates
 
with
 
two
 
power
 
supply
 
CRUs
 
that
 
can
 
be
 
hot-swapped.
 
In
 
the
 
DS4100
 
base
 
storage
 
server,
 
one
 
power
 
supply
 
CRU
 
can
 
maintain
 
electrical
 
power
 
to
 
the
 
unit
 
if
 
the
 
other
 
power
 
supply
 
is
 
turned
 
off
 
or
 
malfunctions.
 
The
 
power
 
supply
 
CRUs
 
are
 
interchangeable
 
(by
 
reversing
 
the
 
locking
 
levers).
 
The
 
DS4100
 
single-controller
 
storage
 
server
 
has
 
only
 
one
 
power
 
supply
 
CRU.
 
You
 
cannot
 
remove
 
or
 
replace
 
a
 
working
 
(non-failed)
 
power
 
supply
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server
 
without
 
first
 
powering
 
down
 
the
 
storage
 
subsystem.
 
Before
 
you
 
replace
 
the
 
power
 
supply
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server,
 
all
 
I/O
 
activity
 
must
 
be
 
stopped
 
and
 
the
 
storage
 
server
 
must
 
be
 
powered
 
down.
 
Go
 
f10ug038
  
Figure
 
65.
 
Removing
 
a
 
fan
 
 
Chapter
 
5.
 
Installing
 
and
 
replacing
 
components
 
89