Справочник Пользователя для IBM Partner Pavilion DS4100

Скачать
Страница из 180
Power
 
cabling
 
The
 
DS4100
 
base
 
storage
 
server
 
uses
 
two
 
standard
 
power
 
cords,
 
and
 
the
 
single-controller
 
storage
 
server
 
uses
 
only
 
one.
 
You
 
can
 
connect
 
the
 
power
 
cords
 
to
 
a
 
primary
 
power
 
unit
 
inside
 
the
 
rack
 
cabinet,
 
such
 
as
 
a
 
properly
 
grounded
 
ac
 
distribution
 
unit,
 
or
 
to
 
an
 
external
 
source,
 
such
 
as
 
a
 
properly
 
grounded
 
electrical
 
outlet.
 
The
 
DS4100
 
storage
 
server
 
does
 
not
 
ship
 
with
 
power
 
cords.
 
Refer
 
to
 
for
 
the
 
list
 
of
 
IBM-approved
 
power
 
cords
 
for
 
your
 
region.
 
Depending
 
on
 
your
 
model,
 
the
 
DS4100
 
storage
 
server
 
does
 
ship
 
with
 
one
 
or
 
two
 
line
 
jumper
 
cords
 
for
 
connecting
 
the
 
DS4100
 
power
 
supply
 
or
 
power
 
supplies
 
to
 
an
 
IBM-approved
 
rack
 
power
 
distribution
 
unit.
 
If
 
you
 
have
 
not
 
already
 
done
 
so,
 
attach
 
the
 
power
 
cords
 
by
 
using
 
for
 
the
 
location
 
of
 
the
 
component
 
parts.
 
 
Perform
 
the
 
following
 
to
 
cable
 
the
 
power
 
cords:
 
1.
   
Connect
 
the
 
power
 
cord
 
to
 
the
 
power
 
supply.
 
2.
   
Remove
 
the
 
nut
 
that
 
holds
 
the
 
power
 
cable
 
strain-relief
 
clamp,
 
and
 
then
 
remove
 
the
 
strain-relief
 
clamp.
 
3.
   
Wrap
 
the
 
strain-relief
 
clamp
 
around
 
the
 
power
 
cord
 
approximately
 
20
 
cm
 
(8
 
in.)
 
from
 
the
 
power
 
supply
 
connection
 
end.
 
Leave
 
some
 
slack
 
between
 
the
 
clamp
 
and
 
the
 
power-supply
 
end
 
of
 
the
 
power
 
cord.
 
4.
   
Replace
 
the
 
power
 
cable
 
strain-relief
 
clamp,
 
and
 
tighten
 
it
 
securely
 
with
 
the
 
nut.
 
5.
   
Plug
 
the
 
power
 
cord
 
into
 
a
 
properly
 
grounded
 
electrical
 
outlet.
 
Note:
  
To
 
maintain
 
power
 
redundancy,
 
plug
 
the
 
storage
 
server’s
 
right
 
and
 
left
 
power
 
supplies
 
into
 
two
 
independent
 
external
 
power
 
circuits
 
through
 
ac
 
distribution
 
units
 
inside
 
a
 
rack
 
cabinet
 
or
 
directly
 
into
 
external
 
receptacles.
 
Similarly,
 
the
 
right
 
and
 
left
 
power
 
supplies
 
of
 
the
 
DS4000
 
storage
 
expansion
 
units
 
attached
 
to
 
the
 
DS4100
 
should
 
be
 
plugged
 
into
 
the
 
same
 
two
 
independent
 
external
 
power
 
circuits
 
as
 
the
 
DS4100.
 
It
 
is
 
recommended
 
that
 
you
 
determine
 
the
 
maximum
 
surge
 
current
 
possible
 
when
 
all
 
devices
 
in
 
the
 
power
 
circuit
 
are
 
started
 
at
 
the
 
same
 
time.
 
Based
 
on
 
the
 
total
 
number
 
of
 
devices
 
on
 
a
 
power
 
circuit,
 
find
 
the
 
maximum
 
(worst-case)
 
specification
 
value
 
in
 
order
 
to
 
prevent
 
the
 
circuit
 
from
 
tripping.
 
When
 
both
 
power
 
supplies
 
are
 
connected
 
and
 
the
 
storage
 
server
 
is
 
powered
 
on,
 
each
 
power
 
supply
 
unit
 
will
 
handle
 
approximately
 
AC power
connector
AC power
switch
Strain-relief
clamp
Lever
-
f10ug027
  
Figure
 
55.
 
Power
 
cord
 
locations
 
 
Chapter
 
3.
 
Cabling
 
the
 
storage
 
server
 
61