Техническая Спецификация для I-Data Electronic Documentation ida

Скачать
Страница из 56
Programming via Shareport
ida FS 250, Operator's Guide
-43-
No.
Name
Syntax
Parameters
119
Auto-
Configura
tion select
%Y119,<n1>%
n1
*0 = Disable Auto-
     configuration
 2 = Auto-
     configuration
     via PJL
120
Settings
printout at
power up
%Y120,n1%
n1
*0= disable settings
    printout at power
    up
 1= enable settings
    printout at power
    up
249
Enter Engine-
ering Mode
%Y249,n1%
n1
password
(contact your local i-
data distributor)
T
Initiate Tests
%T#
1= On-line hex dump
3= ASCII hex dump
4= settings printout
5= printout translate
   table
6= cancel ASCII hex
   dump
X
Save/
Overwrite
Settings
%X#
1= store RAM in
   EEPROM
3= factory default to
   RAM
4= restore settings
   to power up
   defaults
S
Send User
String
%Sn%
1-99 user strings may
     be sent
Z
Send User
String
%Zn
1-8  user strings can
     be sent
W
Bar Code
Printing
%W,<n1>,<n2>%
n1
1-8  Bar code
     definition as
     defined in Y59.
n2
a-z,A_Z,0-9
     Number or
     alphanumeric
     data to be
     printed in bar
     code. Data must
     not exceed one
     line
P
Program Flash
Prom
%P2,area_id,
intel_hex_data%
This function is only
available in
engineering mode
(Y249)