Справочник Пользователя для High End Systems DL.2

Скачать
Страница из 322
CHAPTER 11 
Global Functions
118
DL.2 Digital Light User Manual
Keystone Correction Parameters
When you output an image from a 
projector at an angle, the image 
may appear skewed. Eight 
Keystone parameters 
Top 
Top Left X
Top Right X
Top 
Bottom
Right Y
Bottom Right X
Bottom Left X
Bottom
Left Y
Right Y
Left Y
Original Content
adjust the 
image shape and compensate for 
this effect. You can control each of 
the four corners of the graphics 
output to reshape your image to a 
form that projects correctly. 
Default DMX Value: 0 = no 
keystone correction has been 
applied 
Each corner has an x and a y 
value that adjust and correct scale of the projection from any corner toward the image center 
on that axis. 
Setting all Keystone X and Y parameters DMX values to zero will place the four corners of the 
image at the four corners of the projector output. Adjusting keystone x values toward 255 
(100%) moves the respective corner x positions horizontally toward the center of that image 
edge. Adjusting keystone y values toward 255 (100%) causes the respective corner y positions 
to be moved vertically toward the center of that edge of the image.
Tip: These parameters can also be used to create interesting skewing as a design effect.
Keystone Top Left X DMX value = 85
Keystone Top Left Y DMX value = 85 
Keystone Top Right X DMX value = 85 
Keystone Top Right Y DMX value = 85 
Keystone Top Right Y DMX value = 170
All other Keystone parameter DMX values = 255