Справочник Пользователя для Hitachi 1000

Скачать
Страница из 52
www.hitachi.com
BladeSymphony 1000 Architecture
 
White Paper
37
Module Connections
Chassis A can have up to eight server blades mounted, with two PCI-X slots per server blade. Storage 
modules cannot be mounted on these chassis.
Chassis B can have three types of I/O modules mounted. If a PCI-X I/O Module is installed, the chassis 
can have up to four server blades with four PCI-X slots connected to each server blade, and up to four 
storage modules or server blades with no PCI-X connection. If a PCIe I/O Module is installed, the 
chassis can have up to eight server blades, with up to two PCIe slots per server blade. If a Embedded 
Fibre Channel Switch Module is installed, the chassis can have up to eight server blades, with up to two 
Fibre Channel ports and two gigabit Ethernet ports connected per server blade.
Redundant Power Modules
The Power Module includes a 200-240 VAC input, and supplies the sub- and main-power to the 
system. Up to four Power Modules are installable in a chassis. They are installed redundantly, and 
support hot swapping. The service processor (SVP) checks the power capacity when it starts up. 
If SVD detects redundant power capacity, it boots the system in the normal way. If SVP cannot detect 
Switch & Management Module
1 standard, 2 maximum
1 standard, 2 maximum
I/O Module (PCI-X)
2 maximum
2 slots maximum per server 
blade, 16 slots maximum per 
server chassis
2 maximum
4 slots maximum per server 
blade, 16 slots maximum 
per server chassis
I/O Module (PCIe)
N/A
2 maximum
2 slots maximum per server 
blade, 16 slots maximum 
per server chassis
I/O Module (Fibre Channel Switch)
N/A
2 Maximum
Power Module
4 maximum (N+1 redundant configuration)
Cooling Fan Module
4 standard (3+1 redundant configuration)
USB CD-ROM Drive
Optional
USB Floppy Disk Drive
Optional
Outside Dimension
17.5 x 33.5 x 17.4 inches/ 10 RU
Weight
308 pounds (lbs)
Input Voltage (frequency)
200-240 VAC, single phase (50/60 Hz)
Power Consumption (maximum)
4.5 kW
Operating Temperature
41 to 55 degrees Fahrenheit
Humidity (no condensation)
20 to 80 percent
Module
Type A
Type B