GB-10
NOTE
When the engine fails to start after several attempts 
due to overchoking, open the choke and repeat 
pulling the rope. 
ADJUSTING IDLE SPEED
• The idling speed is set for 2000 rpm at the factory. 
If it is necessary to adjust the idle speed, use the 
adjustment screw on the top side of carburetor.
 
 
 
STOPPING ENGINE
• Move the throttle lever to the idling position and set 
the ignition switch to the stop position.
 
 
 
(1)
NOTE
If the engine won’t stop when setting the ignition switch 
to the stop position, close the choke lever and stop 
the engine.
In this case, please repair the machine at your nealest 
servicing dealer. 
STARTING ENGINE
IMPORTANT
• Avoid operating the blower with the flexible tube 
and swivel joint disconnected. That will reduce the 
cooling air and the engine could be damaged by 
overheating.
1. Push the primer bulb until fuel flows out in the clear 
tube.
2. When the engine is cool, close the choke. 
3. Set the ignition switch to the start position. 
 
 
 
 
(1)
(2)
(3)
(4)
4. Set the throttle lever in 1/3 open position. 
5. To start, hold the top of the blower firmly with your 
left hand. Pull the starter knob slowly until you feel it 
engage and then give it a vigorous strong pull. 
IMPORTANT
• Avoid pulling the starter rope out to its full extent 
and allowing the starter rope to snap back. This will 
prevent premature damage to the starter. 
• Do not let a person stand near the blower or the ex-
haust port. 
6.Once the engine is running, gradually open the 
choke if it was set closed, and let the engine run at 
idle speed for a minute to warm it up.
8. Operation
(1) Choke Lever
(2) Primer Bulb
(3) OPEN
(4) CLOSE
(1) Idling 
  Adjustment Screw
(1) Ignition Switch
(1) Full Throttle
(2) About 1/3 Open
(3) Idling
(4) Ignition Switch
(1) Choke Lever
(2) OPEN
(3) CLOSE