3-1.  OPERATING COMPONENTS
        (Continued)
High Limit
This high temperature control senses the temperature of the
shortening;  if the temperature of the shortening exceeds
450°F (230°C), this control will open and shut off the heat
to the frypot; when the temperature of the shortening drops
to a safe operation limit, the control must be manually reset by
pressing the red reset button, located under the control panel, in the
right, front of the fryer
Filter Drain Pan
The removable pan that houses the filter and catches the shortening
when it is drained from the frypot;  also used to remove and discard
old shortening
When hot shortening is in this pan, use extreme care to
avoid burns.
Filter Union
Connects the filter to the filter pump, and allows easy removal of the
filter and drain pan
Fuses
A protective device which breaks the circuit when the current
exceeds the rated value
3-2.  LID OPERATION
To close lid:
1.
Lower the lid until latch comes into contact with the pot.
To open lid:
1.
Unlatch the front lid latch.
2.       Lift up on handle to raise lid.
3-3.    MELT CYCLE
If the shortening is below 185°F (77°-85°C) with the POWER/
           OPERATION
PUMP switch in the POWER position, the fryer enters the Melt
Cycle.  The shortening is heated slowly to prevent scorching of the
shortening.  The heat cycles on and off to ensure slow melting of
shortening.  At 185°F (85°C) the heat stays on until the Cool Mode
is reached, which is 250°F (121°C).  The controls maintains this
temperature until the COOL button is pressed.
See Filling and Adding Shortening Section.
3-2
      703
Figure 3-1